Load cell U2A with mounted knuckle eyes ZGOW, ZGUW
16
U2A
HBM
A1261−2.2 en/de/fr
Max.
capacity in
[t]
A
min
A
max
F
min
F
max
0.05...0.5
139
156
171
188
1
141
156
173
188
2
212
234
262
284
5
260
288
320
348
10
418
436
541
559
20
466
489
602
625
Max.
capacity in
[t]
Min. depth for
screwing
Tightening
torque M
A
[N
V
m]
B
C
0.05...0.5
9.6
9.6
60
*)
1
9.6
9.6
60
2
16
16
300
5
19.2
19.2
500
10
27
31.2
2500
20
36.6
38.4
4500
*)
Do not exceed this value and handle the load cell with
care during fastening to avoid damage to the thin
measuring diaphragm. Hold the lock nut in place.