Specifications
T40FH
A4429-3.0
HBM: public
67
Nominal (rated) torque
M
nom
300
250
200
150
125
100
kNm
Permissible axial displacement
15)
between rotor and stator
mm
±2
Weight
Rotor
kg
78
142
Stator
kg
2.1
2.3
1)
Option 5, 10 ±5 kHz (code SU2)
2)
Option 5, 60 ±30 kHz (code DU2)
3)
Option 5, 240 ±120 kHz (code HU2)
4)
RS-422 complementary signals, note line termination.
5)
Signal frequency range 0.1 to 10kHz
6)
Output signal range in which there is a repeatable correlation between torque and output signal.
7)
Only for rotating version
8)
Heat conductance via the stator base plate necessary over 70°C. The temperature of the base
plate must not exceed 85°C.
9)
The antenna ring and connector plug must be fixed.
10)
Each type of irregular stress (bending moment, lateral or longitudinal force, exceeding nominal
(rated) torque), can only be permitted up to its specified load limit, provided none of the others
can occur at the same time. If this condition is not met, the limit values must be reduced. If 30%
of the bending moment limit and the lateral limit force occur at the same time, only 40% of the
axial limit force is permissible and the nominal (rated) torque must not be exceeded. The effects
of permissible bending moments, axial and lateral forces on the measurement result are ≤±1%
of the nominal (rated) torque. The load limits only apply for the nominal (rated) temperature
range. At temperatures <10°C, the load limits must be reduced by approx. 30% (strength
reduction).
11)
With static load.
12)
Static and dynamic.
13)
The nominal (rated) torque must not be exceeded.
14)
The influence of radial run-out deviations, eccentricity, defects of form, notches, marks, local
residual magnetism, structural inhomogeneity or material anomalies needs to be taken into
account and isolated from the actual undulation.
15)
Above the nominal (rated) temperature range: ±1.5mm.