11
TIM-PN
ELECTRICAL CONNECTION
7
ELECTRICAL CONNECTION
7.1
General information
To make the electrical connection between the torque transducer and the amplifier, we
recommend using shielded, low-capacitance measurement cables from HBM.
With cable extensions, make sure that there is a proper connection with minimum contact
resistance and good insulation. All plug connections or swivel nuts nuts must be fully
tightened.
Do not route the measurement cables parallel to power lines and control circuits. If this
cannot be avoided (in cable pits, for example), maintain a minimum distance of 50 cm
and also draw the measurement cable into a steel tube.
Avoid transformers, motors, contactors, thyristor controls and similar stray-field sources.
Notice
Transducer connection cables from HBM with attached connectors are identified in accor
dance with their intended purpose (Md or n). When cables are shortened, inserted into
cable ducts or installed in control cabinets, this identification can get lost or become con
cealed. If this is the case, it is essential for the cables to be re-labeled!
7.2
Shielding design
The cable shield is connected in accordance with the Greenline concept. This encloses
the measurement system in a Faraday cage. It is important that the shield is laid flat on
the housing ground at both ends of the cable. Any electromagnetic interference active
here does not affect the measurement signal.
In the case of interference due to potential differences (compensating currents), operat
ingvoltage zero and housing ground must be disconnected on the amplifier and a poten
tial equalization line established between the stator housing and the amplifier housing
(copper conductor, 10 mm
2
wire crosssection).
7.3
Pin assignment
The housing of the TIM-PN has 4 Phoenix Combicon connector blocks, one Ethernet
socket, two PROFINET sockets and two 10+2 sockets/connectors. In delivery condition
the spring-loaded terminals are plugged into the connector blocks.
Содержание TIM-PN
Страница 1: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Mounting Instructions Montageanleitung Notice de montage ...
Страница 3: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Mounting Instructions ...
Страница 62: ...TIM PN SETTINGS 60 Fig 10 32 Service File ...
Страница 73: ...71 TIM PN PROFINET CONFIGURATION WITH THE TIA PORTAL ...
Страница 87: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Montageanleitung ...
Страница 148: ...TIM PN EINSTELLUNGEN 62 Abb 10 32 Service File ...
Страница 160: ...TIM PN PROFINET KONFIGURATION MIT DEM TIA PORTAL 74 ...
Страница 173: ...87 TIM PN TECHNISCHE DATEN Abb 14 1 Abmessungen ...
Страница 174: ...TIM PN TECHNISCHE DATEN 88 ...
Страница 175: ...TIM PN ENGLISH DEUTSCH FRANÇAIS Notice de montage ...
Страница 238: ...TIM PN RÉGLAGES 64 Fig 10 32 Service File Fichier de service ...
Страница 262: ...TIM PN CARACTÉRISTIQUES TECHNIQUES 88 Fig 14 1 Dimensions ...
Страница 263: ...89 TIM PN CARACTÉRISTIQUES TECHNIQUES ...
Страница 264: ...HBK Hottinger Brüel Kjaer www hbkworld com info hbkworld com A04341 06 Y00 00 7 0103 0003 ...