HBK BraggMETER SI Скачать руководство пользователя страница 7

7

FS22SI
INTERROGATOR SETUP

Front view

Back view

Fig. 2.2

The connectors and buttons in 

Fig. 2.2

 are:

1

ON/OFF Button

2

POWER and STATUS LEDs

3

Optical Output Connectors

4

Power Connector

5

Electric fuse

6

Safety Power Button

7

Fans

8

Ethernet Connector

2.2

Turn On

2.2.1

Power

On the Standard format interrogator, connect the provided power adapter to a 100-240 V
power line and the adapter to the interrogator’s power connector. Alternatively, connect
the interrogator directly to  an 11-36 VDC power supply.

Содержание BraggMETER SI

Страница 1: ...FS22SI Industrial BraggMETER SI ENGLISH Quick Start Guide...

Страница 2: ...elos Costa 277 4470 640 Maia Portugal Tel 351 229 613 010 Fax 351 229 613 020 info fs hbkworld com www hbm com fs Mat DVS A04756 05 E00 00 02 2022 Interrogator version v3 SW version v2 6 E Hottinger B...

Страница 3: ...Rack Mountable Format 6 2 2 Turn On 7 2 2 1 Power 7 2 2 2 Ethernet 9 2 2 3 Optical 9 2 3 Turn Off 10 3 Remote Communications 11 4 BraggMONITOR SI Software 12 4 1 Installation 12 4 2 Graphical User In...

Страница 4: ...2 Industrial BraggMETER SI Interrogator Characteristics Material Number Acq Rate Enclosure Connectors Configurable Item Standard Item Static 1S s Standard 1 FC APC K FS22 01 010 120 SC APC K FS22 03 0...

Страница 5: ...ly unit 24 V Ethernet cable L 2m Mounting blocks with M6 screws Connector protection caps Mounting holes protection caps Quick start guide Digital support material Calibration certificate Interrogator...

Страница 6: ...t has the following buttons and connectors Front view Back view Fig 2 1 The connectors and buttons in Fig 2 1 are 1 Optical Output Connectors 2 ON OFF Button 3 Power Connector 4 Ethernet Connector 5 P...

Страница 7: ...tput Connectors 4 Power Connector 5 Electric fuse 6 Safety Power Button 7 Fans 8 Ethernet Connector 2 2 Turn On 2 2 1 Power On the Standard format interrogator connect the provided power adapter to a...

Страница 8: ...replaced Please refer to the full user manual for details The Power LED will acknowledge the power supply by turning green for 2 seconds Fig 2 3 Power LED ON 2s Fig 2 3 Start the interrogator by press...

Страница 9: ...S22SI is 10 0 0 10 Subnet mask 255 0 0 0 S Test the connection Launch a command line e g Start Run type cmd in Windows environment Type and execute the following command ping 10 0 0 10 On a successful...

Страница 10: ...ower LED will start blinking acknowledging the shutdown Power LED blinking at 1 Hz Fig 2 5 Important Pressing the power button between 6 to 10 s will cancel the shutdown Notice Pressing the power butt...

Страница 11: ...strial BraggMETER SI interrogator can be fully controlled using standard SCPI syntax commands The interrogator has 5 different operational states that answer to the listed commands below Fig 3 1 For f...

Страница 12: ...e u To install the software Run Setup exe as administrator u Follow the described steps and press finish u Restart the PC u Run BraggMONITOR SI as administrator 4 2 Graphical User Interface The follow...

Страница 13: ...NITOR SI SOFTWARE 4 2 1 Connect to the Interrogator To establish a connection to the interrogator press the connect button number 1 in Fig 4 1 on the general bar available at the bottom of the softwar...

Страница 14: ...I Interrogator is the threshold see number 3 in Fig 4 2 The get button query the interrogator for the stored value and the set button send the new values to the interrogator and store them The set but...

Страница 15: ...d The threshold value is relative to the maximum peak within each range The definition of the threshold and ranges using the SPD method should use the follow ing steps S Define a value that is high en...

Страница 16: ...FS22SI BRAGGMONITOR SI SOFTWARE 16 Fig 4 3 Upon a finished autoscan independently of the used method the configuration is popu lated with a list of found sensors see Fig 4 4...

Страница 17: ...considering the defined set tings The autoscan searches for peaks and defines those found as sensors For each sensor the autoscan S defines an automatic name CHxSzzz S sets the reference wavelength CW...

Страница 18: ...data is stored in separate files named automatically BraggMONITOR SI Data YYYY MM DD hh mm ss YYYY MM DD hh mm ss txt File interval defines the length of the file in terms of acquisition time Data fol...

Страница 19: ...tted in the graph that is updated every second The sensors to plot can be selected on legend To start saving data to a data file press the save button number 3 in Fig 4 6 Important For further informa...

Страница 20: ...HBK Hottinger Br el Kjaer www hbkworld com info hbkworld com A04756 05 E00 00...

Отзывы: