15
AED
HBM SOFTWARE
6
HBM SOFTWARE
Download the PanelX program from the HBM website's Weighing Technology section:
. Then install the program on your PC.
Follow the procedure below to set up the AED:
u
Connect a transducer to the AED.
u
Connect the AED to your PC.
u
Start the PanelX program.
u
Click on Scan (Fig. 6.1 on page 15).
u
Select the interface you want to use to connect: CANopen, DeviceNet or RS232/485
for the diagnostics bus (Fig. 6.2). If you are connecting the diagnostics bus via a USB-
to-RS232 adapter, select the relevant virtual port for RS232/485.
u
Set the baud rate you will be using.
u
Click on Scan.
This will run the bus scan.
u
If a connection is possible, the AED is displayed below the interface.
u
Click on OK.
Switch to the other program menus to make further settings.
Choose Options
→
User level
→
Administrator to access all the settings.
Fig. 6.1
Accessing the Scan dialog