ELECTRICAL CONNECTION
18
Interface(s)
Power
supply
Digital I/O
AED
24 V 0 V
Power
supply
Optional
PC/master/
slave
Transducer
Optional
Fig. 6.1
Example of shield connection
Tip
A connection diagram is attached with adhesive inside the cover of the basic device.
Notice
For cables 30m long or more, there is a risk that individual bus nodes will have different
ground potentials. In this case, establish a potential equalization between the bus nodes
using a separate cable.
For potential equalization, the best choice is a flexible cable with a minimum conductor
cross-section of 10mm
2
.