Radio Control System

1

Description

The PM NTU transmitter is designed to transmit command instructions for controlling construction, industrial
and mobile cranes, hoists and machines.

Depending on the type and version selected, up to 32 digital or 8 24 digital control
commands plus the integrated safety commands are available to the operator.

A non-interchangeable system address ensures the functional safety of the radio telecontrol system
when operating cranes or machines. This feature is particularly important when several cranes or
machines are in use, for example in halls and shops. The system address is exclusively allocated to
each HBC radio transmitter and its respective receiver.

It is not possible to activate crane or machine functions using a radio system allocated to
another crane or machine.

The transmitter has general telecommunications approvals. It is not necessary to have or to apply
for a license to operate the transmitter with the respective receiver. The transmitter broadcasts in
either a 30 cm or 70 cm bandwidth. The transmitter is equipped with < 10 mW transmitting power.

Operating the PM NTU transmitter using a different frequency range or transmitting power requires
the approval of the competent regulative authorities for telecommunication.

The radio system consists of the PM NTU transmitter, two rechargeable NiCd batteries, a battery
charger and a receiver with antenna. The transmitter housing with integrated antenna is made of
glass-fiber reinforced plastic.

State of the art radio technology complying with the latest guidelines of the FCC and the use of
highly developed microprocessor technology guarantees optimal operating safety, availability and
longevity.

The following radio receiver may be used in conjunction with the PM NTU transmitter:

 

FSE 722 B

 

FSE 735

 

FSE 770

Note :

The improper use, operation or deployment of the device renders the manufacturer guarantee
void of any legal substance !

Содержание PM NTU

Страница 1: ...t notice 2000 08 16 Radio Control System HBC Radio Controls R Ra ad di io o T Tr ra an ns sm mi it tt te er r P PM M N NT TU U for Industrial Cranes made for HBC electronic Funktechnik GmbH Tel 49 0 7...

Страница 2: ...79 51 3 93 50 E mail info radiomatic com http www hbc radiomatic com Distributed by HBC radiomatic Inc 4480 Lake Forest Drive Suite 306 Cincinnati OH 45242 USA Telephone 513 7 33 49 00 Fax 513 7 33 4...

Страница 3: ...4 2 Safety Instructions 5 2 1 Pictographs 5 2 2 General Safety Instructions 6 2 3 Operator Safety Instructions 7 3 Operating Instructions 8 3 1 Battery and Battery Charger 9 3 1 1 FuB 10 AA Transmitte...

Страница 4: ...radio system allocated to another crane or machine The transmitter has general telecommunications approvals It is not necessary to have or to apply for a license to operate the transmitter with the re...

Страница 5: ...disconnected the device from the mains supply supply voltage operating voltage or input terminal voltage Indicates safety relevant passages You will find this pictograph as an indicator for occupation...

Страница 6: ...peration With the first signs of any malfunction related to the operative safety and reliability of the PM NTU radio transmitter the operator must immediately shut down or not activate the transmitter...

Страница 7: ...operator control elements These precautions are particularly important whenever changing your position or climbing over an obstacle Never leave an activated transmitter unattended The operator undert...

Страница 8: ...r use The operator can now issue control commands using the transmitter control elements Whenever the battery is nearly empty the red LED pos lights up or an acoustic signal sounds Replace the drained...

Страница 9: ...to mains confer nameplate on battery charger for details 2 Switch ON the battery charger 3 Insert battery with the type plate facing up into the battery compartment pos Charging indicator red LED pos...

Страница 10: ...nore the following and continue with the next chapter 3 2 1 Scanner With the option scanner the transmitter and the receiver are equipped with 4 radio frequencies each refer to wiring diagrams If the...

Страница 11: ...ption is available for all proportional functions joystick commands Important note Your radio control system was already adapted to your specific crane by a retailer respectively the manufacturer Shou...

Страница 12: ...ve the way the function is carried out as well as the movement of the lever of the hydraulic valve fig above 5 Setting the maximum speed fig right Push the joystick toward the desired function by movi...

Страница 13: ...ver the transmitter is switched ON No operating voltage is present Check the battery contacts for damage or contamination Insert a fully charged battery in battery compartment Recharge battery Low pow...

Страница 14: ...event of any problems with the radio system contact your distributor or HBC radiomatic Inc 5 1 In The Event of a Fault Warning Never operate a crane or machine with a faulty or defective radio system...

Страница 15: ...ddresses over 65 000 combinations Transmitter specific Technical Data Transmitting power FuS 671 3 FuS 680 3 10 mW synthesizer 5 mW synthesizer Transmitter antenna Internal Battery type FuB 10 AA yell...

Страница 16: ...Tel 49 0 7951 393 0 Made in Germany Prod Code SNTU 1 0 Transmitter Ser No 735 IP55 Nema 4 U 6V DC Frequency Band MHz 902 918 W5 FB1 FCC ID NO9 SNTU04 Batt Micron 2977102872 Eco 2977102873 Spec 297710...

Отзывы: