Assembly Instructions M8098-EN
M8098-EN 2018-03
3/6
6.
Proceed as follows in order to remove the covers:
Fig. 3: Flow-5 with ball valve
Fig. 4: Flow-5 view from below
If present disassemble shut-off valve OUT 1 and 4
(Label 3
Disassemble screws (Label 4
Fig. 3), remove cover and
insulation.
Disassemble screws (Label 5
Fig. 3), remove cover and
insulation.
Only in the event of a replacement temperature sensor return
line (BT 2 x):
Disassemble screws (Label 6
Fig. 4) and remove cover.
7.
Replace temperature sensor main line (BT 1) or return line
(BT 2.x) while proceeding as follows:
Fig. 5: Flow-5 side view from the right
Disconnect temperature sensor (BT 1, BT 2.x) at the flow rate
measuring board DFM-51 (A 9.x).
Disassemble temperature sensor (BT 1, BT 2.x) (
Transfer label of temperature sensor to new temperature
sensor (BT 1, BT 2.x) and install(
Connect temperature sensor (BT 1, BT 2.x) at the flow rate
measuring board DFM-51 (A 9.x).
BT 1
BT 2.x
5
3
4
BT 1
BT 2.x