background image

 

 

 

Assembly Instructions M8088-EN 

 

M8088-EN   2020-03 

 

2/3

 

 

  

 

1.

 

Proceed as follows in order to cool down the unit and empty 
the mould (mould evacuation): 

  Display menu page 

Functions

  Select the function 

Cooling

 and activate with the 

 key.

 

  If the function 

Mould evacuation 

is available, select it and 

activate it with the 

 key. 

  The activated function is indicated with the 

 symbol. 

 

  Units HB-100X_4 and HB-100/140/160Z_4 without function 

Mould evacuation

: Loosen the drain connection (G) slowly until 

the unit is depressurized. 

 

2.

 

Main switch off, remove the plug from the mains and empty 
the unit. 

 

 

3.

 

Remove the cover from the unit (see Instruction Manual 
Chapter Maintenance). 

  

4.

 

Loosen the screws in the front panel and hinge it down. 

 

5.

 

Proceed as follows in order to remove the temperature sensor 
(BT 1, BT 2): 

  Unplug cable of the temperature sensor on GIF-51 (A 4) slot 

X 33.1 or X 33.2. 

 

Disassemble and remove the temperature sensor. 

 

 

    

 

WARNING! 

Bolted assemblies, especially combinations of 
stainless steel / stainless steel or steel / stainless 
steel tend to adhere strongly or can seize up after a 
longer period of operation at high temperatures. 
This results in difficulties in dismantling.  

Therefore: 
–  Use a suitable lubricant. 

 

 

6.

 

Proceed as follows in order to assemble the temperature 
sensor (BT 1, BT 2): 

  Mount and fasten new temperature sensor 

  Transfer the cable labelling of the old temperature sensor to the 

new temperature sensor. 

  Plug the temperature sensor on the corresponding slot X 33.1 

or X 33.2 at GIF-51 (A 4). 

 

 

NOTICE! 

The temerpature sensor that is not being changed -
must be cleaned if the demounted temperature 
sensor is showing dirt. 

    

 

Отзывы: