HB Products Covers HBSO Скачать руководство пользователя страница 4

 

 

Instruction manual Ex/ATEX products-02 

July 2021

 

 

 

4 / 6

 

Approvals

 

 

IECEx and ATEX 

IEC 60079-0:2017 
IEC 60079-11:2011 
 

EMC Test 

EMC Emission EN61000-3-2 
EMC Immunity EN61000-4-2 
 

Vibration resistance: 

IEC 68-2-6, 10g, 10 to 2000Hz 
 
Environmental test, incl. 
Damp heat cyclic, Low storage temperature, Sinus vibration, Shock test, Dry heat test, and Cooling 
test. 

Electrical connection and output 

 

 
The electrical connection is normally done using a barrier for additional safety. The sensor is 
connected two wires only as shown here. 
 
Output 
HBSR, HBSC2 & HBSO: 

 approx. 4 mA for off and approx. 20 mA for on 

HBLC, HBLT, HBLS: 

 4 to 20 mA linear to the level from Zero to 100% 

HBX: 

 

 4 to 20 mA linear to vapor quality from dry to end of Span 

 