Selecting Flash Pattern:
▪
Set lamp to Mode 1*
▪
Connect the lamp so that the flash pattern operates
▪
Briefly tap the blue wire to positive [+] for;
➢
<1 second to move to next flash pattern
➢
1~3 seconds to return to previous pattern
➢
3~5 seconds to reset to pattern 1
*Once set the flash pattern is also valid in Mode 2
Available Flash Patterns:
Program
Zone 1
Sequence
Zone 2
Phase
FPM
1
Quad
Synchronised
Quad
1
125
2
Quad
Synchronised
Quad
2
125
3
Double
Synchronised
Double
1
125
4
Double
Synchronised
Double
2
125
5
Single
Synchronised
Single
1
125
6
Single
Synchronised
Single
2
125
7
Quad
Alternating
Quad
1
125
8
Quad
Alternating
Quad
2
125
9
Double
Alternating
Double
1
125
10
Double
Alternating
Double
2
125
11
Single
Alternating
Single
1
125
12
Single
Alternating
Single
2
125
13
-
Constant
-
-
-
14
Quad
Split
Constant
1
125
15
Quad
Split
Constant
2
125
16
Double
Split
Constant
1
125
17
Double
Split
Constant
2
125
18
Single
Split
Constant
1
125
19
Single
Split
Constant
2
125
20
Constant
Split
Quad
1
125
21
Constant
Split
Quad
2
125
22
Constant
Split
Double
1
125
23
Constant
Split
Double
2
125
24
Constant
Split
Single
1
125
25
Constant
Split
Single
2
125
26
Quint
Synchronised
Quint
1
60
27
Quint
Synchronised
Quint
2
60