![HAZET-WERK 9048 P-2 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/hazet-werk/9048-p-2/9048-p-2_operating-instructions-manual_2111531017.webp)
17
HAZET-WERK
Hermann Zerver GmbH & Co. KG
;
Güldenwerther Bahnhofstraße 25 - 29 • 42857 Remscheid •
[
+49 (0) 21 91 / 7 92-0 •
\
+49 (0) 21 91 / 7 92-400 •
^
hazet.de •
]
360°
1. Technical data / tool components
Included in delivery
3
Design and function
9048 P-2/3
Air inlet inside thread
mm (")
12.91 (1/4”)
Weight
kg
0.40
Recommended hose Ø air
mm
10
Recommended hose Ø water
mm
13
Air requirement
L/min
200
Working pressure
bar
6 - 10
PSI
87 - 154
Temperature range
°C
-10 / +40
• 1 x Cooling system flusher
including connection
nipple
• 1 x system cleaning nozzle
• 1 x washing nozzle
• Effective flushing - without use of chemicals
• Multi-functional - replaceable nozzles
• Individual control of both air and water flow
• Great mobility
max.
5 Nm
1
Water regulator
2
Air regulator
3
System cleaning nozzle
4
Washing nozzle
5
3/4” GHT thread
6
Component adapter (1/2 ”/ ø13)
1
2
3
4
5
6
Immer persönliche Schutzausrüstung tragen!
Always wear personal protective equipment!