Replacement Battery Pack for the HD-1100 

Part Number BP-111 

 

 

 
 

 

Figure 2A: Disconnect battery from 
nylon connectors. NOTE: DO NOT 
PULL ON WIRES. 

Figure 2B: Reconnect battery from nylon 
connectors. NOTE: DO NOT PULL ON 
WIRES. 

 

Figure 1: Remove six 
screws 

 

Instructions to replace battery pack 

 

1. Remove optical cover from sensor. 
2. Unscrew the screws on back of HD-1100 housing.  See figure 

1. 

3. After screws are removed gently remove back cover to HD-

1100.  

4. To remove the battery pack, disconnect the nylon connectors 

and remove battery.  See figure 2A. 

5. Insert new battery pack and connect nylon connectors. See 

figure 2B.    

6. Replace back cover of housing and screw back together.   

 

 

 

 

8

Содержание HD-1100

Страница 1: ...SPIRATORY PARTICULATE AIR MONITOR MODEL HD 1100 Environmental Devices Corporation 4 Wilder Drive Bldg 15 Plaistow NH 03865 Tel 603 378 2112 Fax 603 378 2113 E mail customerservice hazdust com Website...

Страница 2: ...INTRODUCTION 3 FEATURES 4 A RANGE SWITCH B ANALOG OUTPUT OPERATION 5 6 A START UP B CHARGING THE UNIT C ZEROING D MONITORING MAINTENANCE 7 8 A CLEANING THE OPTICS B BATTERY REPLACEMENT ACCESSORIES 9 S...

Страница 3: ...from defects in materials or workmanship If a product fails to conform to this one year limited warranty it may be returned to the factory for repair or replacement of the defected part s Environment...

Страница 4: ...es in particle composition and distribution HAZ DUST is calibrated with standard test dust The particle size range is from 0 1 to 50um this represents the EPA PM10 criteria and thoracic region for air...

Страница 5: ...more than 10mg m of dust The range span is from 0 200 mg m B ANALOG OUTPUT Although the DL 103 Data Logger is recommended the 0 2v output can transfer its linear analog voltage to any data logging de...

Страница 6: ...ing the battery status batteries will discharge When charging batteries leave charger connected for 10 12 hours with unit off NOTE Unit should not be connected to charger when off for more than 12 hou...

Страница 7: ...sun light etc When necessary position the unit so that the air intake is opposite bright light Bright fluctuation may produce erroneous data The unit will provide readings in milligrams per cubic met...

Страница 8: ...al if monitoring a concentration of 1 mg m for a period of 8 hours cleaning should be performed every 24 hours It is always recommend checking the zero reading after cleaning Procedures for Cleaning 1...

Страница 9: ...six screws Instructions to replace battery pack 1 Remove optical cover from sensor 2 Unscrew the screws on back of HD 1100 housing See figure 1 3 After screws are removed gently remove back cover to...

Страница 10: ...ption DL 103 Data Logger BP 111 Replacement Battery Pack BC 111 Battery Charger TP 111 Tripod Mounting Stand CS 111 Calibration Standard AS 111 Analog Signal Cable KK 101 Cleaning Kit DA 101 Dust Free...

Страница 11: ...range 0 1 50um Precision 0 02mg m Accuracy 10 Power NiMH battery Operating time 8hrs fully charged Charging time 10 12 hours Signal output 0 2 volts Operating temperature 0 50 degrees Celsius 32 120...

Страница 12: ...products Before returning a unit for servicing a Return Authorization Number RMA number must be issued by Environmental Devices Send all return products to Environmental Devices Corp 4 Wilder Drive B...

Отзывы: