USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
WARNING – Separation Hazard:
Failure to follow safety and operation instructions could result in violent
separation of pump and/or filter components. Strainer cover must be properly secured to pump housing with
strainer cover lock ring. Before servicing pool and spa circulation system, filters manual air relief valve must be in
open position. Do not operate pool and spa circulation system if a system component is not assembled properly,
damaged, or missing. Do not operate pool and spa circulation system unless filter manual air relief valve body
is in locked position in filter upper body. Never operate or test the circulation system at more than 50 PSI. Do
not purge the system with compressed air. Purging the system with compressed air can cause components to
explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume
blower when air purging the pump, filter, or piping.
WARNING – Risk of Electric Shock:
All electrical wiring MUST be in conformance with applicable local codes,
regulations, and the National Electric Code (NEC). Hazardous voltage can shock, burn, and cause death or seri-
ous property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to
electric supply. Provide a properly located electrical receptacle. Before working on any electrical equipment, turn
off power supply to the equipment. To reduce the risk of electric shock replace damaged wiring immediately.
Locate conduit to prevent abuse from lawn mowers, hedge trimmers and other equipment. Do NOT ground to
a gas supply line.
WARNING – Risk of Electric Shock:
Failure to ground all electrical equipment can cause serious or fatal
electrical shock hazard. Electrical ground all electrical equipment before connecting to electrical power supply.
WARNING – Risk of Electric Shock:
Failure to bond all electrical equipment to pool structure will increase risk
for electrocution and could result in injury or death. To reduce the risk of electric shock, see installation instruc-
tions and consult a professional electrician on how to bond all electrical equipment. Also, contact a licensed
electrician for information on local electrical codes for bonding requirements.
Notes to electrician:
Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bond-
ing lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm
2
) [No. 6 AWG (13.3 mm
2
) for Canada] solid
copper bonding wire to the pressure wire connector provided on the electrical equipment and to all metal parts
of swimming pool, spa, or hot tub, and metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside
walls of swimming pool, spa, or hot tub.
IMPORTANT
- Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and
other general wiring procedures.
WARNING – Risk of Electric Shock:
The electrical equipment must be connected only to a supply circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should
be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push reset
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI
interrupts power to the electrical equipment without the test button being pushed, a ground current is flowing,
indicating the possibility of an electrical shock. Do not use this electrical equipment. Disconnect the electrical
equipment and have the problem corrected by a qualified service representative before using.
CAUTION
– HAYWARD
®
pumps are intended for use with permanently-installed pools and may be used with hot
tubs and spas if so marked. Do not use with storable pools. A permanently-installed pool is constructed in or on
the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed
so that it is capable of being readily disassembled for storage and reassembled to its original integrity.
SAVE THESE INSTRUCTIONS