Hayward TriStar SP36075EE Скачать руководство пользователя страница 4

WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

WARNING 

– 

Hazardous Pressure.

  Pool and spa water circulation systems operate under 

hazardous pressure during start­up, normal operation, and after pump shut­off.  Stand clear of circulation 
system equipment during pump start­up.  Failure to follow safety and operation instructions could result in 
violent separation of the pump housing and cover due to pressure in the system, which could cause property 
damage, severe personal injury, or death.  Before servicing pool and spa water circulation system, all 
system and pump controls must be in off position and filter manual air relief valve must be in open 
position.  Before starting system pump, all system valves must be set in a position to allow system water to 

return back to the pool.  Do not change filter control valve position while system pump is running.  Before starting system pump, fully 
open filter manual air relief valve.  Do not close filter manual air relief valve until a steady stream of water (not air or air and water 
mix) is discharged from the valve.  All suction and discharge valves

 MUST

 be

OPEN

 when starting the circulation system.  Failure to 

do so could result in severe personal injury and/or property damage.

 

WARNING 

– 

Separation Hazard.

  Failure to follow safety and operation instructions could 

result in violent separation of pump components.  Strainer cover must be properly secured to pump housing 
with strainer cover lock ring.  Before servicing pool and spa circulation system, all system and pump 
controls must be in off position and filter manual air relief valve must be in open position.  Do not operate 
pool and spa circulation system if a system component is not assembled properly, damaged, or missing.  Do 
not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter 
upper body.  All suction and discharge valves

 MUST

be

OPEN

 when starting the circulation system. 

Failure to do so could result in severe personal injury and/or property damage.

 

WARNING 

 

Never operate or test the circulation system at more than 50 PSI.

 

WARNING 

– 

Fire and burn hazard.

  Motors operate at high temperatures and if they are not properly isolated from 

any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death.  It is also necessary 
to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.

 

WARNING 

 

Failure to install according to defined instructions may result in severe personal injury or death.

 

General Information 

Introduction

 

This manual contains information for the proper installation and operation of the Hayward TriStar Waterfall Pump Series. 
The instructions in this manual

MUST

be followed precisely.

  Failure to install according to defined instructions will void 

warranty. 

Product Benefits

 

The new TriStar Waterfall Pump’s advanced fluid dynamic design operates 60% quiter and consumes 60% less electricity 
than standard single speed pool pumps.  Plus, the heavy­duty pump and motor construction operates cooler for years of 
dependability.  It is the first to feature a Tri­Lock cam and ramp strainer cover design that closes with less than a quarter turn, 
and the TriStar’s super­sized, smooth no­rib basket with extra leaf­holding capacity is easy to clean.

 

TriStar 

™ 

Waterfall Pump Series_________    __ 

______________________________ Page 5 of 15

Содержание TriStar SP36075EE

Страница 1: ...ump for the pool water filtration sanitization system nor is it intended to be used in applications where water will be elevated more than 10 feet above the surface of the water in the pool NOTE To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely IMPORTANT READ CAREFULLY NOTE The TriStar Waterfall pump uses a low speed motor specifically des...

Страница 2: ...ge A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a da...

Страница 3: ...sing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged broken cracked missing or not securely attached can result in a mechanical bind or swelling of the limb Body Suction Entrapment A ...

Страница 4: ...in open position Do not operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and ...

Страница 5: ...lean Pump motors require free circulation of air for cooling Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free Pump mount must Allow pump inlet height to be as close to water level as possible A...

Страница 6: ...t to force hose connector fitting past this stop It is only necessary to tighten fittings enough to prevent leakage Tighten fitting by hand and then use a tool to engage fitting an additional 1 turns Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to tw...

Страница 7: ...swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances are also on the same circuit be sure to add their amp loads before calculating wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it w...

Страница 8: ...ir relief valve See filter owner s manual for more details 4 If water source is higher than the pump pump will prime itself when suction and outlet valves are opened If water source is lower than the pump unscrew and remove strainer cover fill strainer housing with water 5 Clean and lubricate strainer cover O ring with Jack s 327 if necessary 6 Replace strainer cover on strainer housing turn clock...

Страница 9: ...over from strainer housing See Parts Diagram on page 11 of this manual for pump component locations 3 Disconnect pump from mounting pad wiring after power has been turned OFF and piping 4 Once the pump is removed of water re install the strainer cover and drain plugs Store pump in a dry area Shaft Seal Change Instructions IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When s...

Страница 10: ...press it firmly into the recess of the seal plate item 15 with the polished ceramic surface facing out 9 Reassemble the motor to the seal plate item 15 using the four 4 3 8 x 1 bolts item 18 and re attach the motor support item 20 to the seal plate item 15 10 Gently wipe the black polished surface of the spring seal assembly item 13 with a soft cotton cloth 11 Press the spring seal assembly item 1...

Страница 11: ...1 2 SPX3200UG Union Gasket 1 3 SPX3200A Pump Strainer Housing 2 x 2 1 2 with Drain Plugs threaded style 1 4 SPX3200DLS Strainer Cover Kit Includes Strainer Cover Lock Ring O Ring 10 SPX3200DLSB Strainer Cover Kit Biguanide Sanitizer Applications Only NOT Pressure Testable 10 5 SPX3200S Strainer Cover O Ring 10 6 SPX3200M Strainer Basket 15 7 SPX3200Z8 Diffuser Screw 1 8 SPX4000Z1 Diffuser O Ring 1...

Страница 12: ... 1 16 SPX3200Z211 Housing Insert Seal Plate Spacer Kit 1 17 SPX3200Z3 Housing Bolt 10 18 SPX3200Z5 Motor Bolt 1 19 SPX4000FG Drain Plug with O Ring 10 20 SPX3200GA Bracket Motor Support TriStar 1 21 SPX3200SR Base Tall Riser TriStar 1 Pump SKU Detail Model P N Motor P N Impeller P N SP36075EE SPX3605Z1BER SPX3220C SP36120EE SPX3605Z1BER SPX3230CU STA RITE is a registered trademark of Sta Rite Indu...

Страница 13: ... strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring sealing surface is lubricated with Jack s 327 and that strainer cover is locked firmly in position Lubricant will help to create a tighter seal 2 Loose connections on suction side Solution Tighten pipe union connections NOTE Any self priming pump will not prime...

Страница 14: ...any joint low water level in pool and unrestricted discharge return lines Solution Correct suction condition or throttle return lines if practical Holding hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting 2 Vibration due to improper mounting etc Solution Mount the pump on a level surface and secure the pump to the equipment pad 3 Foreign matter in pum...

Страница 15: ...ing the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays To obtain warranty replacements or repair defective components or parts should be returned transportation paid to the place of purchase or to the nearest authorized...

Отзывы: