Zone 1 or 2 ok
ZONE 0
GENERAL
Install the pump at a convenient distance from the edge of the pool to minimize the distance between the suction point and
the pump so as to avoid pointless and excessive load losses in the hydraulic circuit.
This pump can be mount in swimming pool zone 1 or further away as per the conditions of AS/NZS 3000 Wiring Rules.
Install the pump in a ventilated, dry and well drained area that will not flood when it rains. The motor requires air to flow freely
around it to provide natural ventilation for cooling. If installed within an outer enclose or beneath the skirt of a hot tub or spa,
adequate ventilation and free circulation of air must be provided to prevent overheating of the motor.
The pump has to be installed, so that the plug and the wall socket outlet is easily visible and accessible.
The pump must be permanently mounted to a concrete base using lag screws suitable for concrete where pilot holes have
been drilled. Locking washers must be supplied to prevent loosening of the mounting lag screws over time. If the pump is
to be mounted to a wooden deck then lag screws suitable for wood must be used - with lock washers to prevent loosening
over time.
The acoustic level of the Hayward pumps is lower than 70 dB (A).
ELECTRICAL CONNECTION
Make sure that the power supply voltage required by the motor corresponds to that of the distribution network and that the
power supply cables matches the power and current of the pump as in accordance with AS/NZS 3000 Wiring Rules.
Any changes to or installation of power outlets must be done by a qualified electrical contractor.
The supply power is to be supplied by an isolating transformer or supplied through a residual current device (RCD)
having a rated residual operating current not exceeding 30 mA.
The single phase motors fitted to our pumps are provided with thermal protection. This protection operates on an overload
or in the event of abnormal heating of the motor coil and is reset automatically when the winding temperature drops which
allows the pump to automatically restart without warning.