Hayward Spa Heaters Скачать руководство пользователя страница 9

Water piping

The piping sequence is as follows: pool > pool pump > filter > heater > check 
valve  >  chemical  feeder  >  pool.  Automated  chlorine  distribution  systems,  if 
used, must be placed downstream of the heater to minimize harm to the pool 
equipment. Use rigid PVC piping if possible (SCH40 or SCH80). All joints should 
be glued with PVC glue. When the piping installation is complete, operate the 
pool  pump  and  check  the  system  for  leaks.  Then,  check  the  filter  pressure 
gauge to verify that there isn’t any indication of excessive pump head pressure.  

You  can  also  make  the  connections  using  high-pressure  flexible  hose,  but 
make sure the hose can withstand high pressure. The installation of a heat 
pump bypass is not necessary unless the water flow exceeds 75 GPM.

Note:

  Certain  installations  have  valves  which  isolate  the  heat  pump  from  the  water  circuit.  If  the  heat  exchanger 

is deprived of water circulation for several days, high chlorine gas could cause excessive corrosion. If the disconnect 
switch is turned off, be sure that the pool water is allowed to circulate through the unit, or is drained out of it.   

Electrical  

The  wiring  of  your  pool  heat  pump  should  be  performed  by  a  qualified 
electrician in accordance with local requirements.  

Suitable electrical supply line:

 See rating plate on the heat pump units for 

electrical specifications. A junction box is not needed at the heat pump; con-
nections are made inside the heat pump electrical compartment. Minimum 
wire size to be selected per nEC SEC.440.33 based on unit MCA.

An  electrical  disconnect  switch  that  will  interrupt  all  power  to  the  unit  is  
required. This switch MUST be installed within line of sight of the heat pump.

Check the heat pump data label for required maximum breaker size.

The unit must always be powered off before opening the access panel.  

IMPORTANT

?

CAUTION

!

WARNING

7

OWnER’S MAnUAL

Содержание Spa Heaters

Страница 1: ...Owner s Manual 06 2010 13024800 REV C...

Страница 2: ......

Страница 3: ...10 Using an External Controller 11 Electrical Connections 12 Wiring Diagram 13 Service Analyzer Control 14 Operation 15 Caring for your Pool Heater 16 Initial Startup 17 Meaning of Display Codes 18 T...

Страница 4: ...ed the HAYWARD pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally it may be necessary to run t...

Страница 5: ...Please also record the purchase date of your device and your dealer s name address and telephone number Model Number_____________________________________________________ Serial Number_________________...

Страница 6: ...e CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particularly to the pro...

Страница 7: ...lways install the machine outdoors unless otherwise approved by the manufacturer while respecting the minimal clearances needed for proper operation and heating CAUTION Proper pool chemistry is vital...

Страница 8: ...vide a 24 clea rance at the very least all around your heat pump The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum Mount the unit on a sturdy base pref...

Страница 9: ...he water circuit If the heat exchanger is deprived of water circulation for several days high chlorine gas could cause excessive corrosion If the disconnect switch is turned off be sure that the pool...

Страница 10: ...copper rod must be driven into the ground near the equipment All electric and metal components must then be bonded to each other and then to the copper rod CAUTION 1 A 1 3 lb check valve must be inst...

Страница 11: ...Bonding and Plumbing diagram Fig 2 Fig 3 Heat Pump Chemical feeder 9 Owner s manual...

Страница 12: ...ces must be in stalled in a parallel circuit and operated independently only one at a time for your warranty to stay valid NOTICE Because of the intense heat that can be generated by gas and solar uni...

Страница 13: ...t to OFF in POOL mode and to 80 degrees in SPA mode can be controlled with an external switch to heat up to 80 degrees Internal mode Use the P_S mode on the main menu External mode Open contact POOL m...

Страница 14: ...the knock out located on the left or the right side of the base and then insert it in the control box The electrical diagram is located on the lid of the control box as well as in this manual WARNING...

Страница 15: ...ensor High pressure switch Closed OK Opened high pressure Low pressure switch Closed OK Opened low pressure Flow switch Closed flow Opened no flow Orange 240 Vac or Red 208 Vac 24 Vac compressor conta...

Страница 16: ...to parameters To raise the desired temperature or to change parameters To lower the desired temperature or to change parameters Heating mode Compressor or fan running Heating mode Service Analyzer Con...

Страница 17: ...rogram press the SET key until you see P_S and by press ing one of the arrow keys you can switch to POL or SPA Once the heating mode has been programmed it will be displayed for five seconds and will...

Страница 18: ...16 Caring for your Pool Heater How to protect your pool heater Owner s manual...

Страница 19: ...water temperature you desire The fan will immediately start The compressor will start after a 3 to 4 minute delay When the compressor is running the HEATING CHAUFFAGE indicator located on the right se...

Страница 20: ...ckwash filter and or heater The unit will show HP3 after 3 HP faults This will stop your heater for protection Po Water temperature probe connected to WS on the electronic board may be disconnected If...

Страница 21: ...is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying flo and it will not start Heat pump control set to O...

Страница 22: ...ndensation It is normal to see condensation dripping under the heater To check if the water really is a leak you must stop the heater and leave the pool pump running for over 5 hours If water is still...

Страница 23: ...ll your dealer It may save you the cost of a service call If you still need help follow the instruc tions below Service can be obtained by calling one of these phone numbers CANADA 1 888 238 7665 USA...

Страница 24: ...u must turn the breaker off The unit must be drained of all its water You will need to disconnect the IN and OUT water connections Then the unit must be tilted or blown out with air until all water is...

Страница 25: ...ond the normal intended use of the unit or acts of God This warranty is void if the product is repaired or altered in any way by any persons or agencies other than those authorized by HAYWARD and is i...

Страница 26: ...cture date and applies only if the product is installed according to the HAYWARD specifications This warranty does not include the repair of damage due to negligence accident freezing installation in...

Страница 27: ......

Страница 28: ......

Отзывы: