background image

 

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

14

Ref. 

No. 

Part No. 

Description 

  Qty. 

 

MOTORS 

 

 

 

SPX2705Z1M 

Motor, ¾ HP, Threaded Shaft (Single Phase, 60 Cycle 115V/208-230V) 

 

SPX2705Z1ME 

Motor, ¾ HP, Energy Eff. Threaded Shaft (Single Phase, 60 Cycle 115/208-230V) 

 

SPX2707Z1M 

Motor, 1 HP, Threaded Shaft (Single Phase, 60 Cycle 115/208-230V) 

 

SPX2710Z1M 

Motor, 1-1/2 HP, Threaded Shaft (Single Phase, 60 Cycle 115/208-230V) 

 

SPX2715Z1ME 

Motor, 2 HP, Energy Eff., Threaded Shaft (Single Phase, 60 Cycle 115/208-230V) 

 

SPX2707Z2M 

Motor, 1 HP, Two Speed, Threaded Shaft (Single Phase, 60 Cycle 230V) 

 

SPX2710Z2M 

Motor, 1-1/2 HP, Two Speed, Threaded Shaft (Single Phase, 60 Cycle 230V) 

 

SPX2715Z2M 

Motor, 2 HP, Two Speed, Threaded Shaft (Single Phase, 60 Cycle 230V) 

9.

 

Troubleshooting 

9.1.

 

General Problems 

 

Motor Will NOT Start: 
1.

 

Make sure the terminal board connections agree with the wiring diagram on the pump data plate label. 

2.

 

Be sure the pump is wired for the available field supply voltage. 

3.

 

Check for and correct any improper or loose wiring connections; open switches or relays; tripped circuit 
breakers, or blown fuses. 

4.

 

Manually check rotation of the motor shaft for free movement and lack of obstruction.  Correct if necessary. 

 

Motor Shuts OFF: 
1.

 

Check for low voltage or power drop at the motor (frequently caused by undersized wiring).  Contact a 
qualified professional to verify the electrical connections and that the voltage is /- 10% of the motor 
nameplate voltage rating. 

 

Motor Hums, But Does NOT Start: 
1.

 

Check power supply voltage. Contact a qualified professional if the voltage is more than 10% lower than the 
motor nameplate voltage rating. 

2.

 

Impeller jammed with debris.  Have a qualified repair professional open the pump and remove the debris. 

 

Pump Won't Prime: 
1.

 

Empty pump/strainer housing.  Make sure the pump/strainer housing is filled with water & the cover o-ring 
is clean. Ensure the o-ring is properly seated in the cover o-ring groove.  Ensure the o-ring sealing surface is 
lubricated with “Jack’s 327” and that the strainer cover is locked firmly in position.  Lubricant will help to 
create a tighter seal. 

2.

 

Loose connections on the suction side.  Tighten the pipe/union connections. 

 

NOTE - Any self-priming pump will not prime if there are suction air leaks.  Leaks will result in bubbles 
emanating from the return fittings on the pool wall. 

3.

 

Leaking O-ring or packing glands on valves.  Tighten, repair, or replace the valves. 

4.

 

Strainer basket or skimmer basket loaded with debris.  Remove the strainer housing cover or the skimmer 
cover.  Clean the basket, and refill the strainer housing with water.  Tighten the cover. 

5.

 

Suction side clogged.  Contact a qualified repair professional.  You should have 5” - 6” of vacuum at the 
strainer cover (your pool dealer can confirm this with a vacuum gauge).  You may be able to check by 
removing the skimmer basket and holding an object over the bottom port with the skimmer full and the 
pump running.  If no suction is felt, check for line blockage. 

a.

 

If the pump develops a vacuum, check for a blocked suction line or a dirty strainer basket.  An air 
leak in the suction piping may be the cause. 

b.

 

If the pump does not develop a vacuum and the pump has sufficient “priming water”: 

i.

 

Re-check the strainer housing cover and all threaded connections for suction leaks.  Check 
if all system hose clamps are tight. 

ii.

 

Check voltage to ensure that the motor is rotating at full rpm’s. 

iii.

 

Open the housing cover and check for clogging or obstruction in suction.  Check the 
impeller for debris. 

iv.

 

Remove and replace the shaft seal only if it is leaking. 

Содержание SP2305X7

Страница 1: ...Installation and Wiring 5 Start up and Operation 9 Shaft Seal Replacement 10 Replacement Parts 13 Warrantee 15 Registration 16 Basic safety precautions should always be followed including the followi...

Страница 2: ...onding 7 3 9 Wiring 7 4 Startup Operation 8 4 1 Prior to Start Up 8 4 2 Starting Priming the Pump 9 5 Maintenance 9 6 Storage Winterization 9 6 1 Storing Pump For Winterization 10 7 Shaft Seal Change...

Страница 3: ...GENUI NS all instructio y and or death h are damaged s on outlet cover a suction outlet a mechanical b ed to a large po re applied direc n cracked mis y swimsuit ha al entrapment nt Hazards by a perso...

Страница 4: ...e electrical equipment and have the problem corrected by a qualified service representative before using CAUTION HAYWARD pumps are intended for use with permanently installed pools and may be used wit...

Страница 5: ...azard Motors operate at high temperatures and if they are not properly isolated from any flammable structures or foreign debris they can cause fires which may cause severe personal injury or death It...

Страница 6: ...th one to two layers of tape Wind the tape clockwise as you face the open end of the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT at...

Страница 7: ...cal shock if grounded or shorted Reference NEC codes for all wiring standards including but not limited to grounding bonding and general wiring procedures 4 Use a solid copper conductor size 8 or larg...

Страница 8: ...ge plug set for 230 volts Voltage change plug set for 115 volts Fig 3 9 1 Fig 3 9 2 Note Large white arrow is for reference only 5 Reinstall motor end cover WARNING If you do not use conduit when wiri...

Страница 9: ...arranty CAUTION Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES in suction and outlet pipes 3 RELEASE ALL PRESSURE from pump and piping system using filter manual air relie...

Страница 10: ...shaft seal replacement Only qualified personnel should attempt rotary seal replacement Contact your local authorized Hayward Dealer or service center if you have any questions See Parts Diagram Figur...

Страница 11: ...y into the recess of the seal plate item 13 with the polished side of the ceramic facing out 9 Assemble the motor to the seal plate item 13 with the four 4 3 8 bolts item 14 Torque bolts to 100 in lbs...

Страница 12: ...will face up Replace three 3 diffuser screws item 7 Torque screws to 20 in lbs 7 6 Replacing the Motor Assembly 13 Re attach motor end cover canopy by using the two 2 hex shaped screws Slide the motor...

Страница 13: ...4 Housing Bolts Seal Plate Spacers Square Nuts 1 7 SPX2300Z3PAK3 Diffuser Screws 3 Pack 1 8 SX220Z2 Diffuser O Ring 1 9 SPX2300B Diffuser 1 10 SPX2700C Impeller for HP Max Rate Pump 1 SPX2700CSP Impe...

Страница 14: ...rofessional open the pump and remove the debris Pump Won t Prime 1 Empty pump strainer housing Make sure the pump strainer housing is filled with water the cover o ring is clean Ensure the o ring is p...

Страница 15: ...of this equipment Hayward Pool Products Inc warrants its pumps to be free from defects in materials and workmanship for a period of ONE 1 year from the date of purchase when used in single family res...

Страница 16: ...clude me on all e mail communications regarding Hayward Equipment or promotions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LIN...