background image

Page 6 of 8                                              

MODEL S166T,  S166T90 

                                         IS166T90 Rev E 

WWW.HAYWARDPOOL.COM

            USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

PROBLEM SOLVING LIST 

 

LOW WATER FLOW 

SHORT FILTER CYCLES 

POOL WATER WON'T CLEAR UP 

REMEDY 

1. Check skimmer and pump 

1. Check for algae in pool and 

1. Check chlorine, pH and total 

 

strainer baskets for debris. 

2. Check for restrictions in 

intake and discharge lines. 

3. Check for air leak in intake 

line (indicated by bubbles 

returning to pool). 

4. Backwash filter. 

superchlorinate as required. 

2. Be sure chlorine and pH 

levels are in proper range 
(adjust as required). 

3. Check surface of filter sand 

for crusting or caking 
(remove 1 " of sand if 
necessary). 

alkalinity levels and adjust 
as required. 

2. Be sure flow rate through 

filter is sufficient. 

3. Operate filter for longer periods. 

4. Be sure Vari-Flo valve is set 

on "Filter" position. 

 

SUGGESTED POOL CHEMISTRY LEVELS 

pH 

7.2 to 7.6 

TOTAL ALKALINITY 

80 to 120 ppm 

CALCIUM HARDNESS 

200 to 400 ppm 

COMBINED CHLORINE 

0.2 ppm Maximum 

CHLORINE (STABILIZED) 

1.0 to 3.0 ppm 

CHLORINE STABILIZER 

(Cyanuric Acid) 

60 to 80 ppm 

 
 

 
DATE OF INSTALLATION ____________________ 
 
PURCHASED FROM      _______________________ 
 

MODEL _______________  

 

 

SERIAL NUMBER   _______________________ 

         ▲Retain this Warranty Certificate in a safe and convenient location for your records.

 

MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE 

Pipe Size 

[mm] 

Flow rate 
GPM [Liter/Min] 

Pipe Size 

[mm] 

Flow rate 
GPM [Liter/Min] 

Pipe Size 

[mm] 

Flow rate 
GPM [Liter/Min] 

1” 

[32] 

20 
[75] 

1 ½” 

[50] 

45 
[170] 

2 ½” 

[75] 

110 
[415] 

1 ¼” 

[40] 

30 
[110] 

2” 

[63] 

80 
[300] 

3” 

[90] 

160 
[600] 

TABLE 2 

PRODUCT REGISTRATION 

(Retain For Your Records) 

Содержание S166T PRO Series

Страница 1: ...to the potential for personal injury WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about...

Страница 2: ...the suction outlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and...

Страница 3: ...d or service the filter 1 The filter system should be installed not more than 6 feet above pool water level on a level concrete slab very firm ground or equivalent as recommended by your pool dealer P...

Страница 4: ...ng Also use for regular vacuuming BACKWASH For cleaning filter When filter pressure gauge rises 8 10 PSI 0 55 0 69 BAR above start up clean pressure Stop the pump set valve to BACKWASH Start pump and...

Страница 5: ...081 PRESSURE GAUGE 1 3 GMX600F VALVE TANK O RING 1 4 GMX600N FLANGE CLAMP VALVE TANK 1 5 SX202S SAND SHIELD 1 6 SX164DA LATERAL ASSEMBLY W PIPE 1 7 SX164AA2 FILTER TANK W LATERAL ASSY 1 8 SX200QN LATE...

Страница 6: ...uired 2 Be sure flow rate through filter is sufficient 3 Operate filter for longer periods 4 Be sure Vari Flo valve is set on Filter position SUGGESTED POOL CHEMISTRY LEVELS pH 7 2 to 7 6 TOTAL ALKALI...

Страница 7: ...hase Parts which fail or become defective during the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without cha...

Страница 8: ...Page 8 of 8 MODEL S166T S166T90 IS166T90 Rev E WWW HAYWARDPOOL COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS THIS PAGE LEFT BLANK...

Отзывы: