background image

Step 1

Step 2

Step 3

Step 4

Troubleshooting

Download Latest 

Firmware Version

Insert USB into the MSP 

and Enter Service Mode

Press Upgrade and Select 

Component to be Upgraded

Start the Upgrade

  092677 RevC

If a firmware upgrade to your MSP or Wireless Terminal is required...

WARNING - Inserting and removing the USB thumb drive requires re-

moval of the front panel.  Verify that all power is removed to the Omni-

Logic system before removing the front panel.
From your computer:

  To begin upgrading your MSP or your Wireless Ter-

minal (they should have same firmware version), navigate to the website as 

shown in Step 3 on Side A of this sheet.  Insert your USB thumb drive (not 

included) into the computer.  Click on the orange download button located in 

the box of the component that you are upgrading.  Save the firmware file to the 

USB drive. Download the “Wired Terminal” firmware shown below (Wired and 

Wireless Terminals use the same firmware).

When Upgrading your MSP (Step 3, Side A), select:

When Upgrading your Wireless Terminal (Step 6, Side A), select:

NOTE: It is best if you download the firmware in Chrome, Firefox or Safari 

browsers. If you download in Internet Explorer, once your download is com

-

plete, please remove the “.TXT” extension from the file on the USB drive.

Remove the USB drive from the computer once the download is finished.

Verify that power is removed to the OmniLogic system and remove the front 

panel.  Insert the USB drive into the side of the MSP.

Replace the front panel and then power on the OmniLogic system. When 

the system finishes powering back on, enter Service Mode by following the 

screens below.

daylight

favorites

alarm

lights

º

F

air

71º F

82

shut down

service

mode

simple

mode

features

off

NOTE: Do not choose Timed Service Mode when upgrading a device.  If you 

DO choose Timed Service Mode, be sure to dedicate enough time so that the 

upgrade will have time to finish.  Upgrading a Wireless Terminal can take a 

few minutes.

Follow the screens below to begin the upgrade for the device.

SERVICE MODE

main screen

daylight

sysinfo

upgrade

config

select device

component 

 HUA 

 current 

version

MSP 

  00-46-01-21-a0 

 R 

1.5.0 

MP 

  1-65-0-2a-a6 

  R.1.0.4

COMPONENT

selection

Wifi Term 

 

33-41-1-e7-42 

 

R 2.0.0 

select device

component 

 HUA 

 current 

version

MSP 

  00-46-01-21-a0 

 R 

1.5.0 

MP 

 

 

1-65-0-2a-a6  

           R 1.0.4

COMPONENT

selection

Wifi Term 

 

33-41-1-e7-42 

 

R 2.0.0

select file

USB/

FILE

selection

...\ 

Press “Upgrade” button in Ser-

vice Mode menu

Select the device to be up-

graded

Press the check mark

Press “USB” to view the firm

-

ware files on the USB drive

Follow the screens below to finish upgrading the device.  Note that the system 

will restart after upgrading the MSP, not after upgrading the Wireless Terminal.

select file

USB/
MSP_AR_R020100 

FILE

selection

...\ 

select file

USB/
MSP_AR_R020100 

FILE

selection

...\ 

ready to upgrade

component 

 

 

 

firmware file

MSP 

    MSP_AR_R020100  

UPGRADE

firmware

0%

success ready to restart

component 

 

 

 

firmware file

MSP 

    MSP_AR_R020100  

UPGRADE

firmware

100%

Select  the  firmware  file  that 

you downloaded from the web

Press the check mark

Press the check mark to 

begin the upgrade

Press the check mark to 

finish the upgrade once 

it reaches 100%

No Configuration:

 If the Wireless Terminal displays the “Searching for Omni-

Logic” screen shown below, then the OmniLogic system is not discovering the 

Wireless Terminal.  To troubleshoot this issue, follow the steps below.
1.  Verify that the 

OmniLogic

 and the 

Wireless Terminal

 are using the same 

version firmware. If not, upgrade both to the latest versions available at 

www.hayward.com/firmware.   

2.   Verify that the 

OmniLogic

 is connected to your home network and that it 

can be controlled by web or mobile application. Refer to the OmniLogic 

manual for information on how to troubleshoot your home network con

-

nection.

2.   Verify that the 

Wireless Terminal

  is  connected  to  your  home  network. 

Refer to page 3 in your HLWIRELESS manual. You may need to “forget” 

the previously configured access point and reconnect to the network. 

Side B

If the problem persists after following these steps, call the Hayward Technical 

Service Department at (908)-355-7995 for assistance.

Отзывы: