Hayward C-400-1540LSH Скачать руководство пользователя страница 2

Tighten pump base mounting bolts, if loose.

Securely hand tighten the union nut between the
filter and pump.

Connect the pool suction plumbing between the
skimmer, pool outlet and the pump.

Connect the pool return (inlet) plumbing.

If pressure gauge is not installed, apply Teflon tape
to the gauge threads, and carefully screw the
gauge into the threaded hole in the filter cover.

A drain plug is furnished with each filter and is all
that is needed for complete filter draining. A manual
air vent valve is furnished to aid in bleeding off
unwanted air when starting the filter.

All electrical connections should be made in
accordance with local codes.

Check for joint leaks before operating the system.

Refer to pump instruction booklet for pump
information. 

4.

5.

6.

7.

8.

9.

10.

11.

12.

PARTS

Models C-400-1540LSH,

C-400-1575 and C-550-1575

SERIES  SYSTEMS

REF.

NO.

1

2

3

4

5

6

7

8a

8b

9a

9b

10

11

12

13

14

15a

15b

16

17

18

NO.

REQ’D.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

PART

NO.

EXC2710

ECX1322-A

ECX4077-B-1

CX400-C

CX400-BA

CX400-G

CX400-D

CX410-RE

CX550-RE

CX400-AA

CX550-AA

SX200-Z-8

SX200-Z-9

SP-1480

SP-1575-1

SPX1425-Z-6

SPX1500-WA

SPX1550-WA1

ECX1108

ECX1109

ECX1161

DESCRIPTION

Gauge

Vent Valve w/O-Ring

Check Valve

Locking Ring

Filter Head (Cover),

w/Check Valve and

Locking Ring

Filter Head (Cover)
O-Ring

Locking Ring Latch

Filter Element (40 Sq. Ft.)

Filter Element (55 Sq. Ft.)

Filter Body (C-400)

Filter Body (C-500)

Drain Cap

Gasket

1-1/2

Male Union

Power-Flo LX Pump

O-Ring

6 Ft. Cord Set

3 Ft. Twist Lock Cord Set
(Not Shown)

Pump Mounting Screw

Washer

Platform Base

a

a
b

a
b

Содержание C-400-1540LSH

Страница 1: ... making connections use plastic male end adapters Apply three turns of Teflon tape or plastic pipe sealant to the male threads Screw the fitting into the threads hand tight then using a wrench tighten one more full turn Additional tightening is unnecessary and could result in damaged components Refer to the diagrams for suggested valving Ball type valves are recommened where needed IS 400 1540 98 ...

Страница 2: ...ing the system Refer to pump instruction booklet for pump information 4 5 6 7 8 9 10 11 12 PARTS Models C 400 1540LSH C 400 1575 and C 550 1575 SERIES SYSTEMS REF NO 1 2 3 4 5 6 7 8a 8b 9a 9b 10 11 12 13 14 15a 15b 16 17 18 NO REQ D 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 PART NO EXC2710 ECX1322 A ECX4077 B 1 CX400 C CX400 BA CX400 G CX400 D CX410 RE CX550 RE CX400 AA CX550 AA SX200 Z 8 SX200 Z ...

Страница 3: ... and turn clockwise until it engages and is secured by the safety latch Proceed as in STARTING THE FILTER Cleaning Cartridge The cartridge filter element can be cleaned by pressure washing inside and out with Hayward s Jet Action Cleaning Wand EC 2024 or a garden hose Rotate cartridge hosing from top down The cartridge is easier to clean when dry After hosing the cartridge for best results allow c...

Страница 4: ... and can then be removed by the filter Live algae on the other hand multiplies so fast that the filter cannot keep up with its growth rate When correctly used commercial algaecides are effective against algae though algaecides should be used in conjunction with and not as a substitute for regular chlorination or superchlorination Maintaining a chlorine level of at least 0 5 ppm in the pool water a...

Отзывы: