Hayward Aqua Solar GL-235 Скачать руководство пользователя страница 2

Installation

Mounting

The GL-235 is designed for outdoor use.  Mount the box vertically with the knockouts

facing downward.  For safety, the GL-235 must be a minimum of 5 feet (horizontally) from

the pool or spa.

Power input

Turn off power at circuit breaker before wiring.  Remove the internal panel to expose

the wiring connections.  Either 115VAC or 240VAC can be used.  Refer to the input wiring

diagram (Figure 1) on next page.  

WARNING:  Applying 240VAC to the 120VAC input

terminals will cause permanent damage to the control.

Grounding

Refer to NEC and local codes for specific grounding requirements.  In general, a separate

ground conductor must be run to the ground terminal on the pool service panel.

Low Voltage (LV) output:  Solar Valve

The GL-235 controls a single valve.  In most applications this is the solar valve, which

diverts water through the collector panels or through the normal pool loop depending

on conditions.

All controls are shipped with the output voltage set to the industry standard 24VAC.

To use the GL-235 with older 12VAC valves, move jumper J4, located on the right side

of the circuit board.

Description

The GL-235 is a differential temperature control for solar heating of pools, spas, and hot

tubs.  It provides differential temperature control with an adjustable, calibrated water

temperature high limit.  Automatic nocturnal cooling (for pools that overheat in hot

climates) and recirculate freeze protection functions can be enabled/disabled via

internal jumpers.

Input power can be either 115 or 240 VAC.  The output controls a 24VAC automatic valve

actuator.  For older systems with 12VAC valves, an internal jumper can be moved to

select 12VAC output operation.  The GL-235 also has a high voltage output for

controlling a filter pump or booster pump.

Specifications

Temperature/Resistance/Voltage

All Hayward controls use 10K thermistor sensors.  When disconnected from the control

the sensor will read 10K ohms at 25ºC/77ºF.  Refer to the chart below for the resistance

at other temperatures.   For a given temperature, the resistance reading should be

accurate to ±1%.  For a given resistance reading, the temperature reading should be

accurate to ±0.5ºF.  Voltage measurements should be accurate to ± 2%.   Ohm

measurements made with sensor disconnected from unit.  Voltage measurements made

with sensor connected to unit and power applied.  Sensor voltages are DC volts.

2

11

°F

Ohm s

V olts °F

Ohm s

V olts

°F

Ohm s

V olts

°F

Ohm s

V olts

1

82,719

 4.46

41

25,391

 3.59

81

9,076

   

2.38

121

3,679

   

1.34

2

80,142

 4.45

42

24,704

 3.56

82

8,861

   

2.35

122

3,602

   

1.32

3

77,656

 4.43

43

24,037

 3.53

83

8,651

   

2.32

123

3,527

   

1.30

4

75,255

 4.41

44

23,391

 3.50

84

8,447

   

2.29

124

3,454

   

1.28

5

72,937

 4.40

45

22,764

 3.47

85

8,249

   

2.26

125

3,382

   

1.26

6

70,698

 4.38

46

22,156

 3.45

86

8,056

   

2.23

126

3,312

   

1.24

7

68,535

 4.36

47

21,566

 3.42

87

7,867

   

2.20

127

3,244

   

1.22

8

66,447

 4.35

48

20,993

 3.39

88

7,684

   

2.17

128

3,177

   

1.21

9

64,428

 4.33

49

20,438

 3.36

89

7,506

   

2.14

129

3,112

   

1.19

10

62,479

 4.31

50

19,900

 3.33

90

7,333

   

2.12

130

3,049

   

1.17

11

60,595

 4.29

51

19,377

 3.30

91

7,164

   

2.09

131

2,987

   

1.15

12

58,774

 4.27

52

18,870

 3.27

92

6,999

   

2.06

132

2,926

   

1.13

13

57,014

 4.25

53

18,377

 3.24

93

6,839

   

2.03

133

2,867

   

1.11

14

55,313

 4.23

54

17,899

 3.21

94

6,683

   

2.00

134

2,809

   

1.10

15

53,669

 4.21

55

17,435

 3.18

95

6,530

   

1.98

135

2,752

   

1.08

16

52,078

 4.19

56

16,985

 3.15

96

6,382

   

1.95

136

2,697

   

1.06

17

50,541

 4.17

57

16,548

 3.12

97

6,238

   

1.92

137

2,643

   

1.05

18

49,054

 4.15

58

16,123

 3.09

98

6,097

   

1.89

138

2,591

   

1.03

19

47,616

 4.13

59

15,711

 3.06

99

5,960

   

1.87

139

2,539

   

1.01

20

46,225

 4.11

60

15,310

 3.02

100

5,827

   

1.84

140

2,489

   

1.00

21

44,879

 4.09

61

14,921

 2.99

101

5,697

   

1.81

141

2,440

   

0.98

22

43,577

 4.07

62

14,543

 2.96

102

5,570

   

1.79

142

2,392

   

0.97

23

42,318

 4.04

63

14,176

 2.93

103

5,446

   

1.76

143

2,345

   

0.95

24

41,099

 4.02

64

13,820

 2.90

104

5,326

   

1.74

144

2,299

   

0.93

25

39,919

 4.00

65

13,473

 2.87

105

5,208

   

1.71

145

2,254

   

0.92

26

38,777

 3.97

66

13,136

 2.84

106

5,094

   

1.69

146

2,210

   

0.90

27

37,671

 3.95

67

12,809

 2.81

107

4,982

   

1.66

147

2,167

   

0.89

28

36,601

 3.93

68

12,491

 2.78

108

4,873

   

1.64

148

2,125

   

0.88

29

35,565

 3.90

69

12,182

 2.75

109

4,767

   

1.61

149

2,084

   

0.86

30

34,561

 3.88

70

11,882

 2.72

110

4,664

   

1.59

150

2,044

   

0.85

31

33,590

 3.85

71

11,589

 2.68

111

4,563

   

1.57

151

2,005

   

0.84

32

32,648

 3.83

72

11,305

 2.65

112

4,464

   

1.54

152

1,966

   

0.82

33

31,737

 3.80

73

11,029

 2.62

113

4,368

   

1.52

153

1,929

   

0.81

34

30,853

 3.78

74

10,761

 2.59

114

4,274

   

1.50

154

1,892

   

0.80

35

29,998

 3.75

75

10,500

 2.56

115

4,183

   

1.47

155

1,856

   

0.78

36

29,169

 3.72

76

10,246

 2.53

116

4,094

   

1.45

156

1,821

   

0.77

37

28,365

 3.70

77

9,999

   

2.50

117

4,007

   

1.43

157

1,787

   

0.76

38

27,587

 3.67

78

9,758

   

2.47

118

3,922

   

1.41

158

1,753

   

0.75

39

26,832

 3.64

79

9,525

   

2.44

119

3,839

   

1.39

159

1,720

   

0.73

40

26,100

 

3.61

80

9,297

   

2.41

120

3,758

   

1.37

160

1,688

   

0.72

Power

:

105-130VAC, .5A 50/60Hz.

            or

195-250VAC, .3A 50/60Hz

Output:

Selectable low voltage

24VAC, 20VA, .85A

or

12VAC, 20VA,1.7A

SPST-NO isolated contact

115VAC 1HP

240VAC 2HP

Sensors:

 2 required  (thermistor,

                       10Kohm @  25C/77ºF).

Differential

: on at 4ºF, off at 1.5ºF

Desired

Pool

Temp.:

70-104ºF calibrated scale

or Solar Off, 75 (24ºC) -

104ºF (40ºC) on some

models

Recirculate

freeze

:

On at <40ºF (4.5ºC), off at

> 42ºF

(5.5ºC),

Enabled via jumper

Nocturnal

cooling:

On when collector 8ºF

less than pool and pool

hotter than limit, off when

collector 3ºF less than

pool or pool cooler than

high limit. Enabled via

jumper

With the sensor disconnected from the unit, measure the resistance of the sensor using

an ohmmeter.  At room temperature (25ºC/77ºF) the sensor should measure approxi-

mately 10K  ohms (10,000 ohms ± 1%).  For other resistance measurements at different

temperatures, consult the table at back of manual.  If the sensor is not returning the

correct value, it is defective and will need to be replaced.  If the sensor is returning

approximately the correct value, reconnect it to the terminals marked “SOLAR SEN-

SOR”.  If the “CHECK SENSOR” indicator remains on, the unit is defective and needs

to be replaced.

If FREEZE PROTECTION is enabled:

When a sensor is disconnected from the unit and freeze protection has been enabled,

the GL-235 will recognize this as a freeze condition and activate freeze protection.

Отзывы: