DUAL SUCTION OUTLET SET
ISDUALSWG REV D
INSTALLATION INSTRUCTIONS: -
Use a #2 Philips head Screwdriver.
NOTICE:
When installing WG1030AVPAK2 refer to
ASME A112.19.8-2007 for the proper instructions on
how to construct the field-fabricated sump. Figure 2 is an illustration of some of the requirements.
Suction outlets for a pool with a vinyl liner and for fiberglass pools are provided with a WG1048B mounting
ring and two (2) gaskets. The gaskets should be placed such that they sandwich the liner or fiberglass, that is,
one gasket on each side. The ring (WG1048B) is attached to the suction outlet by eight (8) screws that pass
through both gaskets and the liner. See diagram below.
Suction outlets for a concrete or gunite pools are
designed to be plastered with the top surface flush
to the pool surface. An Adjustable Collar
WG1051X may be used to aid in obtaining the
desired configuration.
Two screws MUST be used to secure the cover to
the suction outlet. USE ONLY HAYWARD GENUINE
REPLACEMENT PARTS INCLUDING THE SCREWS.
For installations utilizing a hydrostatic relief valve
(SP1056), using a collector tube (SP1055) will maintain a clear path to the hydrostatic valve. At least one
hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water
to be relieved into the pool or spa.