background image

Page 4 of 8 

              

DUAL SUCTION OUTLET SET 

ISDUALSWG REV D

 

 

 

   

 

 

INSTALLATION INSTRUCTIONS: - 

Use a #2 Philips head Screwdriver.

 

NOTICE:

  When installing WG1030AVPAK2 refer to

 

ASME A112.19.8-2007 for the proper instructions on 

how to construct the field-fabricated sump. Figure 2 is an illustration of some of the requirements. 
 
Suction outlets for a pool with a vinyl liner and for fiberglass pools are provided with a WG1048B mounting 
ring and two (2) gaskets.  The gaskets should be placed such that they sandwich the liner or fiberglass, that is, 
one gasket on each side.  The ring (WG1048B) is attached to the suction outlet by eight (8) screws that pass 
through both gaskets and the liner.  See diagram below.   

 

Suction outlets for a concrete or gunite pools are 
designed to be plastered with the top surface flush 
to the pool surface.  An Adjustable Collar 
WG1051X may be used to aid in obtaining the 
desired configuration. 
 
Two screws MUST be used to secure the cover to 
the suction outlet.  USE ONLY HAYWARD GENUINE 
REPLACEMENT PARTS INCLUDING THE SCREWS. 

 
  
 
 

For installations utilizing a hydrostatic relief valve 

(SP1056), using a collector tube  (SP1055) will maintain a clear path to the hydrostatic valve.  At least one 
hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water 
to be relieved into the pool or spa. 

Содержание WG1048AVPAK2

Страница 1: ...ailure to follow instructions can cause severe injury and or death This is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal wor...

Страница 2: ...ch of two separate vertical walls See Diagram 2 o Dual suction fittings shall be placed in such locations and distances to avoid dual blockage by a user o Dual suction fittings shall not be located on...

Страница 3: ...locity in the interconnecting piping is only 3ft sec the same pipe size is required in the interconnecting piping Example In the System shown in Diagram 2 one 1 Floor Only suction outlet cover rated a...

Страница 4: ...is attached to the suction outlet by eight 8 screws that pass through both gaskets and the liner See diagram below Suction outlets for a concrete or gunite pools are designed to be plastered with the...

Страница 5: ...IPE PLUG 1 0 4 SPX1053Z1 2 IN PLASTIC PIPE PLUG 1 0 WG1053AVPAK2 WG1054AVPAK2 2 NPT Bottom Plug WG1051AVPAK2 WG1052AVPAK2 1 NPT Bottom Plug NOTES NOTES WG1048AVPAK2 WG1049AVPAK2 1 NPT Bottom Plug WG10...

Страница 6: ...ER SUCTION OUTLET 1 0 2 WG1048EW COVER SUCTION OUTLET 1 0 3 WGX1058C ROUND FRAME 1 0 SP1153AVPAK2 SP1154AVPAK2 2 NPT Bottom Plug NOTE WG1153AVPAK2 WG1154AVPAK2 SPARE COVER INCLUDES SCREWS FOR ALL VARI...

Страница 7: ...thout the express written authorization of Hayward Pool Products To original purchasers of this equipment Hayward Pool Products warrants its vacuum release systems to be free from defects in materials...

Страница 8: ...NSTALLATION ____________________ Retain this Warranty Certificate upper portion in a safe and convenient location for your records DETACH HERE Fill out bottom portion completely and mail within 10 day...

Отзывы: