background image

Page 2 of 8                                       

                                                             

                          IS170TSC Rev B 

WWW.HAYWARDPOOL.COM

            USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

 

WARNING

 - 

Read and follow all instructions in this owner’s manual and on the equipment. Failure to 

follow instructions can cause severe injury and/or death

 

WARNING

 

– Suction Entrapment Hazard.  

Suction in suction outlets and/or suction outlet covers which are, damaged, broken, cracked, missing, or unsecured can cause severe injury 
and/or death due to the following entrapment hazards: 

Hair Entrapment

- Hair can become entangled in suction outlet cover. 

Limb Entrapment

- A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked, 

missing, or not securely attached can result in a mechanical bind or swelling of the limb. 

Body Suction Entrapment

- A negative pressure applied to a large portion of the body or limbs can result in an entrapment.  

Evisceration/ Disembowelment 

- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or 

suction outlet cover which is, damaged, broken, cracked, missing, or unsecured can result in evisceration/ disembowelment. 

Mechanical Entrapment

- There is potential for jewelry, swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a 

suction outlet cover resulting in mechanical entrapment.

 

 

WARNING

 

To Reduce the risk of Entrapment Hazards:

 

When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be 
installed.  Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’)  [1 meter] apart, as 
measured from near point to near point. 

Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by a user. 

Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. 

The maximum system flow rate shall not exceed the flow rating of as listed on Table 2. 

Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. 

Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. 

In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards and CPSC guidelines, follow all 
National, State, and Local codes applicable. 

Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended. 

 

WARNING

 

 

Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction 

outlets can result in an increase potential for suction entrapment as described above.

 

 

WARNING

 

– Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other 

material can result in an increase potential for suction entrapment as described above.

 

 

WARNING

 

– Suction outlet components have a finite life, the cover/grate should be inspected frequently and replaced 

at least every ten years or if found to be damaged, broken, cracked, missing, or not securely attached.

 

 

CAUTION

 

– Components such as the filtration system, pumps and heater must be positioned so as to prevent their 

being used as means of access to the pool by young children.

  

 

WARNING 

– Never operate or test the circulation system at more than 40 PSI.

 

 

CAUTION

 

– All

 

electrical wiring MUST be performed by a qualified professional, and MUST conform to local codes 

and regulations.

 

 

WARNING 

– Never change the filter control valve position while the pump is running.

 

 

 

WARNING 

– Hazardous Pressure.

 

 Pool and spa water circulation systems operate under hazardous pressure during 

start up, normal operation, and after pump shut off.  Stand clear of circulation system equipment during pump start up.  Failure to 
follow safety and operation instructions could result in violent separation of the pump housing and cover, and/or filter housing and 
clamp due to pressure in the system, which could cause property damage, severe personal injury, or death.  Before servicing pool and 

spa water circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position.  Before 
starting system pump, all system valves must be set in a position to allow system water to return back to the pool.  Do not change filter control valve 
position while system pump is running.  Before starting system pump, fully open filter manual air relief valve.  Do not close filter manual air relief 
valve until a steady stream of water (not air or air and water) is discharged.

 

 

WARNING

 

 

Separation Hazard.

  

Failure to follow safety and operation instructions could result in violent separation of 

pump and/or filter components.  Strainer cover must be properly secured to pump housing with strainer cover lock ring.  Before servicing 
pool and spa circulation system, filters manual air relief valve must be in open position.  Do not operate pool and spa circulation system 
if a system component is not assembled properly, damaged, or missing.  Do not operate pool and spa circulation system unless filter 
manual air relief valve body is in locked position in filter upper body.

 

 

 

WARNING

 

– Electrical

 

Ground motor before connecting to electrical power supply.  Failure to ground pump motor can 

cause serious or fatal electrical shock hazard.

 

 

WARNING

 –

 

Do NOT ground to a gas supply line.

 

Содержание Dream Line S170TSCPE

Страница 1: ...ld cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or p...

Страница 2: ...on outlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other mate...

Страница 3: ...ce the filter 1 The filter system should be installed not more than 6 feet above pool water level on a level concrete slab very firm ground or equivalent as recommended by your pool dealer Position th...

Страница 4: ...e for regular vacuuming BACKWASH For cleaning filter When filter pressure gauge rises 8 10 PSI 0 55 0 69 BAR above start up clean pressure Stop the pump set valve to BACKWASH Start pump and backwash u...

Страница 5: ...a SX180HG Drain Cap Assy 1 5 16 Dia 9b SX180LA Drain Cap Assy 1 3 4 Dia 1 10 SX180K System Mounting Base 1 11 SPX11050Z4 1 Elbow Adapter 1 12 SPX1091Z2 1 Straight Hose Adapter 1 13 SX160Z3 Hose 1 14 E...

Страница 6: ...STRY SUGGESTED POOL CHEMISTRY LEVELS TO RAISE TO LOWER pH 7 2 to 7 6 Add Soda Ash Add Muriatic Acid or Sodium Bisulphate TOTAL ALKALINITY 100 to 130 ppm Add Sodium Bicarbonate Add Muriatic Acid CHLORI...

Страница 7: ...anty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective product ba...

Страница 8: ...Page 8 of 8 IS170TSC Rev B WWW HAYWARDPOOL COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS THIS PAGE LEFT BLANK...