background image

HAWS AG 

x

 Bachweg 3 

x

 CH-3401 Burgdorf 

x

Switzerland 

x

 www.haws.ch

HAWS Corporation 

x

 P.O.Box 2070 

x

 1455 Kleppe Lane 

x

 Sparks,Nevada 89431/USA 

x

 www.hawsco.com

HAWS DRINKING FAUCET COMPANY

FITTINGS AND OPERATING INSTRUCTIONS

2077580

HW8.50ES5551

Jeannine Ruf

03.06.2013

2/2

No.

Model 

HW8.50ES5551      

Water Cooler

MODEL: HW SERIES

Installation and Maintenance Instructions

INSTALLATION

CAUTION

:Care should be taken not to puncture refrigeration system lines. The lines contain gas

1.

under high pressure.

IMPORTANT

:While it is quite common to ground electrical equipment to waterlines, a potential

2.

problem arises when water coolers are connected to these water lines. An electrolytic condition will

often occur which results in the drinking water have a metallic taste. To prevent this from

happening, place a dielectric coupling in the water supply line between the mains and the cooler

being installed, and also put in a plastic drain trap.

WATER SUPPLY

:3/8" O.D. copper inlet line connection with strainer. IMPORTANT:Flush building

3.

water supply line to remove all foreign matter before cooler is connected. Warranty claims will not be

accepted if a clear water supply can not be guaranteed, it is recommended to install a HAWS filter.

WASTE CONNECTION

:1" O.D. tube - installer must provide a waste trap and comply in

4.

accordance  with local codes.

ELECTRICAL CONNECTION

:Cooler supplied with power cord and NEMA 5-15 plug. Ensure power

5.

supply data is exactly the same as voltage, frequency, and phase specified an nameplate. Make 

sure the electrical supply is provided with a grounding (earthing) conductor. NEVER wire compressor 

directy to the power supply.

MATERIALS NOT FURNISHED

:Drain trap, shut off valve and mounting screws.

6.

VENTILATION

: A 4" clearance beyond cooler louvers is required for proper ventilation. Failure to

7.

comply with this clearance requirement may cause compressor failure and void warranty. (Not 

required for water-cooled units).

START UP

:Fill the cooler with water. Before plugging unit into electrical supply, make sure fan blade 

8.

rotates freely (Nor required for water-cooled units).

MAINTENANCE

IMPORTANT

:All service must be performed by an authorized service person.

1.

APPEARANCE

:Clean top and cabinet with mild cleaning agent.

2.

LOUVERS

:Keep clean and free of paper, debris and dust to assure good operation.

3.

ADJUSTMENTS

:

4.

Water flow regulator

:remove front panel, locate regulator mounted an front brace, rotate

adjustment screw clockwise to raise stream height.

Cold thermostat control

:remove front panel, locate thermostat mounted an left side panel

and rotate adjustment screw clockwise to lower water temperature. Rotate counter-clockwise

to natural stop to turn unit OFF.

Hot thermostat control

:(if applicable) nonadjustable.

STORAGE OF COOLER

:All water must be drained from cooler before storing, especially in areas 

5.

subject to freezing temperatures (This includes models with water-cooled condensers). 

Отзывы: