![Haws H1107.8 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/haws/h1107-8/h1107-8_installation-operation-and-maintenance-instructions-manual_2110184002.webp)
03/20
Model H1107.8
Page 2 of 7
RECOMMENDED TOOLS
: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open
end wrench.
LOCATION OF UNIT:
The Model H1107.8 Cooler is a wheelchair accessible drinking water
facility. The height dimensions shown, meet current ADA requirements. When installing this
unit, local, state or federal codes should be adhered to. If height other than shown is
required, then dimensions must be adjusted accordingly.
SUPPLY LINE
: The minimum recommended line size is 1/2
“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet is 3/8” O.D. push-in type fitting. Waste trap outlet is
female 1-
1/4” IPS.
ELECTRICAL CONNECTIONS
: 115VAC, 60HZ, 4.7 AMPS. Chiller wired direct to incoming
line, by others.
PARTS LIST
MODEL PACKAGE
QUANTITY
ITEMS INCLUDED
MTGFR.7
1
Mounting Frame (Required
– Sold
Separately)
3
#10 Sheet Metal Screws
HCR8
1
Chiller
H1107.8
1
Bowl Assembly
1
Package supply tubing assembly and
2 fittings
1
Panel-bowl back
1
Grille
1
Trap 1-1/4
” IPS
1
Package of two each: grille
attachment, attachment clips, clip
nuts, #10 sheet metal screws and 6-32
screws
4
5/16 -18 retainer nuts
4
5/16
– 18 x 1 hex head screws
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL PLEASE CALL:
TECHNICAL SUPPORT:
1-800-766-5612
FOR CUSTOMER SERVICE:
1-888-640-4297