10/08
Model 8905
Page 2 of 4
LOCATION OF UNIT
: The Model 8905 Hose Spray should be installed in close proximity to
potential accident areas. It should be clearly identified free from obstructions and easy to
access.
SUPPLY LINE:
The minimum recommended line size is 1/2" IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet supply is 1/2” NPT.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
No flow.
1.
a.
Check the main shut-off valve.
2.
Insufficient water flow.
2.
a.
Verify minimum 30 psi (2 ATM) flowing
supply line pressure.
b.
Probable clogging of flow control due to
inadequate line flushing. Unscrew
eye/face wash head and remove the
four screws to disassemble the head.
Clean flow control and reassemble
head. See SP65 Installation Drawing for
details.