APPROVED:
DRAWN:
PART NUMBER
SCALE:
SHEET
OF
REVISION
DRAWING TYPE:
SIZE: A
BY:
ECN NO.
PAG
E
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
MJ
06/30/16
16
0002080045.D
PORTABLE EYEWASH
7501/7501T/7501T240
1:1
2
2
MJ
05/29/18
5086
MJ
8 O
F
8
INSTALLATION
5235
2018
VWC
46 1/4" - 66 1/4"
[1175mm - 1683mm]
TO FINISHED FLOOR
FLOOR
LINE
STAND BY
"OFF"
POSITION
ACTIVE
"ON"
POSITION
DO NOT EXCEED WATER FILL LINE.
REFER TO INSTALLATION
INSTRUCTIONS IN "OPERATION AND
MAINTENANCE MANUAL" FOR
PROPER FILLING PROCEDURES.
NOTES: (CONTINUED FROM SHEET 1 OF 2)
(FOR MODEL 7501T240)
8. CORD SET SHALL BE LISTED TO UL 817 AND CSA-C22.2 NO. 21 AND PROVIDED WITH 3 WIRE
GROUNDING TYPE ATTACHMENT PLUG RATED 240 V, MIN. 15 A.
9. THE FLEXIBLE CORD TYPE SHALL BE TYPE S, SE, SJ, SJE, SJO, SJOO, SJT, SJTO, SJTOO, SO, SOO, ST,
STO, OR STOO AND HAVE A TYPE LETTER SUFFIX OF "W," "W-A" OR "OUTDOOR."
10. THE CORD SET SHALL BE MIN. 6 FT IN LENGTH AND MIN 18 AWG SIZE FOR FLEXIBLE POWER SUPPLY
CORD.
11. LISTED STRAIN RELIEF BUSHING SUITABLE FOR CORD SET SIZE AND OUTDOOR USE SHALL BE USED.
12. ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE (30mA GFEPD) FOR HEAT TRACE.
ELECTRICAL CURRENTS MAY BE INSUFFICIENT TO TRIP A CONVENTIONAL CIRCUIT BREAKER. ALL
INSTALLATIONS MUST BE INSTALLED IN COMPLIANCE WITH LOCAL, STATE, AND/OR FEDERAL CODES.
13. ALL POWER CONNECTIONS MUST BE MADE ACCORDING TO NEC/ CEC CODE USING FLEXIBLE
CONDUIT OR CABLE RATED FOR NEMA/TYPE 4 – NO RIGID CONNECTION PERMITTED. MODEL 7501T240
REQUIRES MINIMUM NEMA/TYPE 4 COMPLIANT EQUIPMENT.
14. THE FIELD INSTALLED POWER SUPPLY CORD SET NEEDS TO BE INSTALLED BY QUALIFIED
PERSONNEL.
4 3X 1/4" MOUNTING
HARDWARE
(NOT SUPPLIED)
3X Ø 5/16"
Ø [8mm]
MOUNTING
BRACKET
(SUPPLIED)
1/2" THICK
SPACERS
6
7501T SUPPLIED
WITH GFCI 8'
POWER CORD
(120VAC, 60Hz,
200W)
OVER-TEMP
THERMOSTAT
* 18"
[457mm]
* 12-1/2"
[318mm]
1 1/8"
[29mm]
2 1/4"
[57mm]
* 24"
[610mm]
* 8"
[203mm]
1 1/4"
[32mm]
* 15-3/4"
[400mm]
* 22"
[559mm]
MODELS 7501T/7501T240 - WITH HEATED BLANKET SHOWN.
FOR MODEL 7501 SEE SHEET 1 OF 2.
MOUNTING DETAILS FOR:
33" - 53"
[838mm - 1346mm]
FLOW PATTERN
4
FOR 7501T: MUST USE WITH NEMA/TYPE 3R
CERTIFIED COVERED OUTLET (NOT SUPPLIED).