Haws 7501 Скачать руководство пользователя страница 1

 

 

03/18 

Model 7501/7501T/7501T240 

Page 1 of 8 

 

 

 

 

      No. 2080045(16) 

 

1455 Kleppe Lane 

Sparks, NV 89431-6467 

(775) 359-4712 

Fax (775) 359-7424 

E-mail: 

[email protected]

 

 

website: 

www.hawsco.com

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Model 7501/7501T/7501T240 

Portable Eyewash/Portable Eyewash with Heater 

 

INSTALLATION, OPERATION 

MAINTENANCE INSTRUCTIONS 

 

 

LIMITED WARRANTY

 

 

HAWS warrants that this specific product is guaranteed against defective material or poor 
workmanship for a period of 

one year from date of shipment

. HAWS liability under this 

warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any 
goods, or part thereof, which shall appear to the Company upon inspection to be of 
defective material or not of first class workmanship, provided that claim is made in writing 
to Haws within a reasonable period after receipt of the product. Where claims for defects 
are made, the defective part or parts shall be delivered to the Company, prepaid, for 
inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or 
for any expense connected therewith made by the owner or his agents, except upon 
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages 
caused by defective materials or poor workmanship, except for replacements, as 
provided above. Buyer agrees that Haws has made no other warranties either expressed 
or implied in addition to those above stated, except that of title with respect to any of the 
products or equipment sold hereunder and that HAWS shall not be liable for general, 
special, or consequential damages claimed to arise under the contract of sale. 
 
The emergency equipment manufactured by HAWS is warranted to function if installation 
and maintenance instructions provided are adhered to. The units also must be used for 
the purpose for which they were intended. This product is intended to supplement first-aid 
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this 
emergency equipment will prevent serious injury or the aggravation of existing or prior 
injuries

 

NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR GIVEN BY HAWS.

 

 

NOTE TO INSTALLER: Please leave this information with the Maintenance Department. 

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF 
THIS MODEL PLEASE CALL: 
 

      

TECHNICAL SUPPORT:

 

1-800-766-5612 

 

FOR CUSTOMER SERVICE:    

1-888-640-4297 

Содержание 7501

Страница 1: ...ts except upon written authority from HAWS Sparks Nevada HAWS will not be liable for any damages caused by defective materials or poor workmanship except for replacements as provided above Buyer agrees that Haws has made no other warranties either expressed or implied in addition to those above stated except that of title with respect to any of the products or equipment sold hereunder and that HAW...

Страница 2: ...ONNECTIONS reference manual supplied with heating blanket Model 7501T 120VAC 60 Hz 1 38A Requires a three prong outlet and is supplied with a heavy duty 8 foot power cord with GFCI plug Unit is suitable for installation and use in NEMA TYPE 3R areas Must be used with NEMA TYPE 3R certified covered outlet not supplied DURING POTENTIAL FREEZING PERIODS INSURE THAT UNIT IS CONNECTED TO A CONTINUOUS P...

Страница 3: ...e lowered position See Installation Drawings pages 7 and 8 of 8 Filled eyewash unit is heavy approximately 80 pounds Wall bracket anchors Quantity 3 not supplied must be strong enough to support the filled eyewash and the weight of a worker leaning on eyewash STEP 4 Fill up to fill line see important note above Requires 8 75 gallons max of water make sure that no debris or contaminants of any kind...

Страница 4: ...ome water loss will occur due to natural evaporation process STEP 2 Take proper precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks We recommend either of the following procedures NOTE Disconnect Model 7501T 7501T240 from power source before performing maintenance Procedure A Use suitable Sterile Antimicrobial Preservative Model 9082 to help prevent the growth o...

Страница 5: ... reached b Make sure unit is level from front to back and left to right 5 Eyewash flows for less than 15 minutes 5 Fill water level in eyewash tank even with water fill line indicated on side of unit 6 Excessive water loss 6 Check unit for leaks Some loss due to evaporation is normal 7 Heater doesn t turn on Model 7501T 7501T240 7 a Not plugged in or no power to outlet Check GFCI plug 7501T only a...

Страница 6: ...BY ECN NO PAGE DATE DATE ECN REVISED PER CHKD Haws Corporation All Rights Reserved HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation C R MODEL S 1455 KLEPPE LANE SPARKS NEVADA 89431 775 359 4712 FAX 775 359 7424 E MAIL HAWS HAWSCO COM WEBSITE WWW HAWSCO COM ITEM DESCRIPTION THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION CONTINUED PRODUCT IMP...

Страница 7: ...2mm DO NOT EXCEED WATER FILL LINE REFER TO INSTALLATION INSTRUCTIONS IN OPERATION AND MAINTENANCE MANUAL FOR PROPER FILLING PROCEDURES 4 4 MODEL 7501 SHOWN FOR MODELS 7501T 7501T240 WITH HEATED BLANKET SEE SHEET 2 OF 2 FLOOR LINE MOUNTING DETAILS 33 53 838mm 1346mm FLOW PATTERN NOTES 1 WHEN INSTALLING THIS UNIT LOCAL STATE OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS LOCATIONS...

Страница 8: ...E SJ SJE SJO SJOO SJT SJTO SJTOO SO SOO ST STO OR STOO AND HAVE A TYPE LETTER SUFFIX OF W W A OR OUTDOOR 10 THE CORD SET SHALL BE MIN 6 FT IN LENGTH AND MIN 18 AWG SIZE FOR FLEXIBLE POWER SUPPLY CORD 11 LISTED STRAIN RELIEF BUSHING SUITABLE FOR CORD SET SIZE AND OUTDOOR USE SHALL BE USED 12 ALL MODELS MUST HAVE A GROUND FAULT PROTECTION DEVICE 30mA GFEPD FOR HEAT TRACE ELECTRICAL CURRENTS MAY BE I...