10/08
Model H1001.8/H1001.8HPS
Page 2 of 7
RECOMMENDED TOOLS
: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 3/32” and 5/32 “ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or
open end wrench.
LOCATION OF UNIT:
The Model H1001.8/H1001.8HPS Cooler is a wheelchair accessible
drinking facility. The height dimensions shown, meet current ADA requirements. When
installing this unit, local, state or federal codes should be adhered to. If height other than
shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE
: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Inlet is 3/8” O.D. tube. Waste elbow outlet is 1-1/4” O.D. tube.
ELECTRICAL CONNECTIONS
: 115VAC, 60HZ, 4.7 AMPS. Chiller wired direct to incoming
line, by others.
PARTS LIST
MODEL PACKAGE
QUANTITY
ITEMS INCLUDED
MTGFR.SM 1
Mounting
Frame
3
#10 Sheet Metal Screws
HCR8 1
Chiller
H1001.8/H1001.8HPS 1
Bowl
Assembly
1
Package supply tubing and two (2)
fittings
1
Grille
1
Package of two each-grille attachment
clips, clip nuts, #10 sheet metal screws
and 6-32 screws
4
5/16 -18 retainer nuts
4
5/16 – 18 x 1 hex head screws
1
Waste elbow 1-1/4” O.D.
INSTALLATION PROCEDURE
GENERAL NOTES:
The Model H1001.8/H1001.8HPS Water Cooler assembly requires installation of the mounting
frame as described in Steps 1 - 2, then mounting the fountain bowl assembly as described in
Steps 3 - 6, and finally completing chiller water and electrical connections and starting chiller per
Steps 7 - 11. First check that all required parts are received.
Grounding may cause electrical feedback into the electric drinking fountain causing an
electrolysis, which creates a metallic taste or an increase in the metal content of the
water. This condition can be avoided by using dielectric couplings in the assembly. The
waste line, which is supplied by the installer, should also have a dielectric (plastic)
coupling to completely isolate the assembly from the building plumbing system.
For all plastic push-in type fitting connections; push tubing into fitting until it bottoms
out to ensure a watertight connection. To remove, depress the collet and pull tubing out.