RECOMMENDED TOOLS:
-
Measuring Tape
-
PVC Pipe Cutter
-
Plastic Tubing Cutter
-
PVC Solvent Weld Glue
-
¼” Bit-Holding Screwdriver
-
Level
-
10
” Pipe Wrench
-
Adjustable Plier
-
1/8 and 5/32 Tamper Resistant Hex Bits (Supplied)
-
9/16
” and 5/8” Box/Open Combination Wrenches, 8” Max Length
-
3/8
” Socket Wrench/Rachet, 8” Max Length
-
9/16
” Deep Socket
-
15/16
” Socket
LOCATION OF UNIT:
The Model 3602FR Drinking Fountain can be installed and assembled
to be ADA accessible by first locating the pedestal base with at least 8 inches of clear
unobstructed hardscape behind the pedestal. Provide hardscape that is at least 74 inches
wide. When the right pedestal arm is installed in the high orientation, the height dimensions
shown on the model specification sheet meet current Federal Americans with Disabilities Act
(ADA) wheelchair requirements. When a fountain is installed on top of the pedestal, the height
dimensions shown on the model specification sheet meet current ADA standing height
requirements. When installing this unit, local, state and federal (including ADA) codes must
be adhered to. If height other than shown is required, then dimensions must be adjusted
accordingly.
SUPPLY LINE:
The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS:
Water supply inlet connection is a 3/
8“O.D. compression fitting.
Waste outlet is 1-
1/2” PVC pipe. Plumbing connections vary depending on how the unit is
configured during assembly. Please consult the installation drawings below for supply and
waste fitting arrangements and assembly for your specific model.
MAINTENANCE:
Refer to 6518.2FR Operation and Maintenance Sheet for more information.
INSTALLATION PROCEDURE
Follow the installation procedures outlined in the installation diagrams for your specific model
below. Note: 3602FR version must be connected to Haws Model 6518.2FR freeze resistant
bury valve, sold separately. See 6518.2FR installation manual for instructions.
GENERAL NOTES:
1. For all compression fitting connections, only connect NSF-61 copper or plastic
3/8
” outside diameter tubing. The following assembly instructions must be
followed to ensure a watertight connection:
a. Cut tubing square and clean. Deburr if necessary.
b. Place compression nut and ferrule over end of tubing.
c. For plastic tubing (must be
¼” inside diameter), insert supplied tubing
insert into end of tubing.
d. Push tube into the fitting until it bottoms out.
e. Thread nut onto fitting and tighten snugly with 5/8
” wrenches.