09/21
MODEL 1001HO
PAGE 3 OF 5
general notes for proper connection procedures for push-in type fittings). Connect
3/8
” O.D. tube between supplied tee and fountains and solenoid valve outlet(s) (if not
already connected). See installation drawing at the end of this manual for supply
plumbing and wiring details.
STEP 2
: Open screwdriver-stop
wide open
while checking for leaks at all connections. Also,
check waste for leaks.
STEP 3
:
Model 1001HO: 5867 Valve Pressure Regulator
–
Adjust bubbler stream height
using the black pressure regulator mounted inside bracket with HO sensor unit, by
loosening the locknut and rotating the knob clockwise to increase flow or
counterclockwise to reduce flow. Tighten the locknut and check flow height. Repeat
these steps until the bubbler flow height is correct.
STEP 4: 1RKHO.H Transformer and Sensor Setup: Refer to the 1RKHO.H manual for
instructions (supplied).
MAINTENANCE
STEP 1:
Periodically clean out the supply line Y-strainer.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. Insufficient bubbler flow.
1a. Check that inlet screwdriver stop valve (not
supplied) is in wide-open position.
b. Verify minimum 30 psi flowing supply pressure.
c. Clean Y-Strainer.
d. Clean screens (inside nozzle body). Unscrew
nozzle insert and very gently activate water
supply to pop out qty. 3 screens (be careful not
to lose screens). Remove any debris clogging
the screen openings and place back into nozzle
body. Reassemble nozzle insert.
For more information about Haws products, see our website: