LIMITS OF USE

This charger is designed to be used in a sheltered area. It is designed
exclusively to recharge lead batteries in an industrial environment. 

PRODUCT  RECYCLING - DESTRUCTION

When this charger becomes obsolete, it can be recycled or destroyed by
authorized facilities. Local regulations will prevail and must be followed.

MODIFICATIONS AND IMPROVEMENTS

EnerSys

®

reserves the right, at any time, to modify or improve its 

products, without any obligation to update this product or this manual
accordingly. 

RECEIVING - STORAGE

Upon receipt, please inspect visually the exterior of the charger for any
physical damage. If necessary, proceed within 24 hours with the usual
claims procedure with the transport company.

If the charger is to be stored before use, it should remain in the original
packaging, carefully closed. Store in a clean, dry area at a moderate 
temperature (0 °C to +40 °C). If the equipment is stored at a temperature
below 15°C, it must be gradually (24 hours) restored to operating 
temperature before use, to prevent the risk of condensation that 
could cause electrical faults and short-circuits.

SPARE PARTS

Please supply the unit’s serial number, indicated on the information plate
when ordering any spare parts.

INFORMATION PLATE

Located on either side of the charger.

GLOSSARY

Charger Features

The EnerSys chargers are managed by a microprocessor. 
The microprocessor can calculate the battery capacity and automatically
sets the appropriate charging profile. This allows the charger to work
over a wide range  of battery capacities. The control of the charging 
factor is absolute on all battery types. The Life IQ

TM

chargers adapt to 

battery capacity and depth of discharge.

Charge factor

Charge factor is the quantity of Ampere Hours returned to the battery
during the charge cycle versus the amount removed during the last
discharge.

Refresh Charge 

A refresh charge maintains the battery at the optimum level as long as it
is connected to the charger.

Desulphation charge

A desulphation charge is done prior to normal charging, and this 
charge restores the specific gravity of over-discharged or under-utilised
batteries.

Equalisation charge

Done after the normal charge, a balancing charge that ‘equalises’ the cell
voltages and specific gravity of all cells in the battery.

Wi-IQ

®

This device, permanently installed on the battery, wirelessly transmits
battery parameters to the charger in order to optimise the charge and to
manage the charge and discharge data.

Communicated parameters are:
Temperature, battery capacity, warnings (water  level, voltage balance),
voltage, charging status …

The Wi-IQ also transmits data of the battery temperature during the 
charging process and will possibly stop the charge if the temperature is
too high.

Charging profile

Defines the profile of the current applied to the battery during charging
in relation to available time. Diverse charging profiles can be selected.
The charger adapts to the battery based on capacity and state of charge
and age in order to maximize overall battery life. The control of the 
overcharge factor, whatever the battery depth of discharge, provides a
reduction in water consumption (except on VRLA batteries) and energy
consumption .

Ionic profile

Also called “Ionic Mixing” this profile consists of applying short current
pulses to the battery, thus provoking gassing in the active material to 
diffuse the sulphuric acid from the plates. This introduction of Ionic 

Mixing enables faster charging of the battery and eliminates the 
differences in density by homogenizing the electrolyte throughout 
the cells. The ionic profile doesn’t require weekly equalisation charge.

Gel battery profile

The procedure for charging sealed, maintenance-free batteries has 
been optimised to ensure that the particular requirements necessary for
recharging are observed. The main advantages of these batteries are
that there is no necessity to add water, thus reducing maintenance costs,
and no necessity for special charging rooms (subject to local regulations)
with ventilation and water demineralisation units.

Water Less

®

/Water Less

®

20 battery profile

The charging procedure for Water Less batteries has been optimised in
order to provide more flexibility and more time due to longer topping 
up intervals.

Pneumatic battery profile
PzM profile (Water Less)        - 65 cycles 
WL20 profile (Water Less 20) - 100 cycles 

This type of battery is fitted with an air injection circuit allowing 
electrolyte circulation. The electrolyte circulation system reduces the
charging time and the water consumption.

EC DECLARATION OF CONFORMITY

EnerSys hereby declares that the chargers in the 
Life IQ range covered by this declaration conform to:

Directive 2006/95/EC

(Low Voltage Directive) :

EN60950-1

Directive 2004/108/EC

(ElectroMagnetic Compatibility) :

EN61000-6-2, EN61000-6-4 :
Immunity and emissions limits for industrial electronics
(class A- Industrial Environments)

Directive 2002/95/EC

(RoHS)

Содержание Life IQ

Страница 1: ...1 Technical Manual GB Hawker Life IQTM Single phase and 3 phase chargers ...

Страница 2: ...irectly in contact with water Must be used only within the temperature range specified in the technical specifications Internal connection torques must be checked once a year Must not be installed on a surface subject to high vibration levels proximity of motors compressors etc Must not be installed close to the batteries in order to avoid any gassing that could damage it prematurely Must not be i...

Страница 3: ...ansmits battery parameters to the charger in order to optimise the charge and to manage the charge and discharge data Communicated parameters are Temperature battery capacity warnings water level voltage balance voltage charging status The Wi IQ also transmits data of the battery temperature during the charging process and will possibly stop the charge if the temperature is too high Charging profi...

Страница 4: ...m for safe disconnection during the charge A USB interface enables the connection of a USB stick to download all data stored in the charger optionally fitted with Ethernet interface for remote management of the charger EXTERNAL COMPONENTS Presented below Single phase model 3 phases model Ref Function 1 Ventilation louvres 2 Display and control panel 3 AC input cable 4 Battery cable 5 Wall mounting...

Страница 5: ...e battery temperature will be analysed during the charge if it increases too much the charger will stop to prevent any possible damage High temperature Defines the safety limit in high temperatures Without Wi IQ not used With Wi IQ If the battery temperature during the charge reaches the programmed limit the charger will stop the charge and wait until the temperature decreases Charge Profile For s...

Страница 6: ... Region Selects the format for date metric imperial units for temperature and length Contrast Modifies the display contrast level Change Password Changes the password PASSWORD Manages a password to limit access to charger menu INFORMATION Gives information on the software version memory and time clock USING THE CHARGER UNPACKING The charger is delivered with the following 2m AC mains cable 3m DC b...

Страница 7: ... be 230V AC single phase or 400V AC 3 phase and must be connected using a suitable plug and adequately sized circuit breaker not included Current requirements in Amps are indicated on the charger information plate Battery output It is essential to ensure correct polarity However reversed polarity will result in blowing the output fuse inability to charge and the fault code DF2 to be displayed See ...

Страница 8: ...to the connected battery and counts down the time remaining until the effective charge begins Ref Without Wi IQ With Wi IQ 1 Charger status CHARGE AVAIL DEFAULT EQUAL possible pump fault or DF4 2 Alternating display of battery voltage voltage per cell Ah restored charging time remaining charging time percentage of battery charge 3 Set up operating battery T C Battery temperature and and battery ca...

Страница 9: ...vel DF PUMP Fault in the air circuit Check the proper operation of of the electrolyte the pump via the menu circulation system Option Option test Check the air circuit pump tubes If this fault occurs the charger will adapt the battery charging profile for a safe optimised charge TH Thermal problem in Verify the correct operation of charger resulting in the fans check for too high charge interrupti...

Страница 10: ...closely with our customers and suppliers to identify development opportunities Our bias for rapid innovation means we get new products to market fast EnerSys s integrated sales and service network is dedicated to providing our customers with the best solutions and after sales support for their business Whether you require 1 battery or a complete fleet of batteries chargers a battery handling syste...