Hawk HA-MC01 Скачать руководство пользователя страница 5

 

IN

STA

LLAT

IO

N OF M

AIN 

SYSTEM

 CO

MPO

NEN

TS

 

 

Grea

t c

are

 has

 bee

n t

ak

e in

 th

e de

sign an

d m

anu

fa

ctur

e o

f HA

WK

 product

s, 

Corre

ct 

in

stall

ati

on

 an

d good work

ing 

prac

tices wil

l en

ha

nc

e th

e op

era

tio

n of the al

arm s

ystem

 

and 

giv

e l

ong te

rm b

en

efi

t to th

e u

se

r. 

 

1.

 

po

siti

on

 and at

ta

ch

 th

e C

on

tro

l u

nit

 

2.

 

po

siti

on

 an

d at

ta

ch

 the 

LE

D Alarm

 in

dic

ato

r  

 

ALAR

M WIR

IN

G  

 

Plan

 wh

ere 

to m

ak

e th

e co

nn

ecti

ons

 to

 th

e mo

torc

yc

le

 w

iri

ng

 lo

om

. The al

arm l

oom

 

sh

ould 

run a

lo

ngsi

de

 th

e origin

al m

oto

rcy

cle l

oom ta

kin

g fu

ll a

dv

an

tage 

of t

he 

mo

to

rcyc

le w

irin

g lo

om in

tegrity

. N

orm

ally

 all c

on

nec

tion

s ca

n be m

ade to a

 c

en

tra

l area

 

on

 the 

mo

torc

yc

le

 lo

om

, su

ch

 a

s u

nd

er th

e pe

tro

l tan

k.  

NO

TE

: So

ldered j

oin

ts

 ar

e rec

omm

ended 

fo

r a

ll w

irin

g c

on

necti

ons.

    

 

 

AL

ARM

 WIRIN

G INS

TALLAT

ION 

 

IMPO

RT

ANT 

Ma

ke sur

e t

ha

t yo

u ha

ve pla

nned 

th

e wir

ing co

nn

ec

tio

ns

 befo

re a

da

pti

ng

 / cutting

 th

alarm

 lo

om or 

th

e m

oto

rcyc

le lo

om

.  

 

 

1.

 

Co

nn

ect R

ED 

wire 

to co

nstan

t p

ow

er i

np

ut (

+) 12

v sup

ply

 from

 the b

att

ery. 

2.

 

Co

nn

ect BL

ACK w

ire to 

any w

ire in

 th

e ig

nit

ion

 sys

tem wh

ich 

becom

es live w

he

th

e ig

nit

ion is sw

itched ON

, a

nd 

re

ma

ins liv

e wh

en the 

star

ter is press

ed e.g.

 

power

 fe

ed fro

m ig

nition 

switc

h t

o fuse

 box.  

3.

 

Co

nn

ect O

RA

NG

E w

ire 

to le

ft i

nd

ic

ato

r po

siti

ve

 (+

) l

ead

 outp

ut.

 

Ta

ke

 ca

re

 n

ot to

 

use th

e mo

torcycle

 indicator

 negative (-) 

wire

4.

 

Co

nn

ect L

IG

HT

 BLUE

 wire 

to righ

t in

dic

ato

r po

siti

ve

 (+

) outp

ut.

 

Take ca

re

 not to

 

use th

e motorcycl

e indicat

or negative (-

) wir

e. 

5.

 

Co

nn

ect Y

ELL

OW

/R

ED

 w

ire 

to the r

em

ote s

tar

ter (

+) 

le

ad ou

tput.

 

6.

 

En

gine i

mmo

bilisat

io

n

- th

ere

 are

 2 ca

bles

 1) B

LA

CK/

WH

IT

E  wir

e 2) 

WH

ITE

/BL

ACK wi

re. R

ec

om

men

ded c

irc

uits

 ar

e th

e fu

el pum

p or fu

el pum

p rela

y. 

If in 

doubt

 which

 circ

uit

 to

 im

mo

bilise

, co

nsider 

an

y circuit

 th

at 

th

e m

oto

rc

ycle 

ma

nu

fac

turer

 use

s t

o s

wit

ch off

 th

e eng

ine

, suc

h a

s kill s

wit

ch, fa

ll do

wn se

nsor, 

side stan

d swit

ch

 e

tc

. (

 Th

e CP

U on It

ali

an

 m

oto

rcyc

les o

r t

he H

all

 Effec

t ign

iti

on

 

on Harley

 D

av

idson

s is 

no

t rec

omme

nd

ed.)   

7.

 

Co

nn

ect G

RE

EN e

arth

 wir

e to th

e m

otorc

yc

le

 fr

ame or th

e b

attery

 n

eg

ati

ve

 

term

in

al. 

8.

 

Conn

ec

t sma

ll 

2 pin co

nn

ect

or 

to

 LED 

9.

 

Blu

e wire 

fo

r op

tion

al n

egat

ive 

inpu

t sen

sor e.g.

 tilt

 or mic

rowa

ve

 sens

or 

10.

 

Co

nn

ect l

arg

e 2 pi

n co

nne

ctor 

to Sir

en

  

Wiri

ng

 Diag

ra

 

 

 

 

ANTI HIJACK 

 
Press the 

  

button for 2 seconds when ignition is on engine will immobilise 

immediately, siren will sound continuously and indicator lights will flash continuously.   
Press the 

 

button

 

to de-activate anti hijack mode.  

 
 

FOUR –SELECTION SENSITIVITY SET

 

When alarm disarmed Press the 

  

button and the  

  

button at the same time, the 

siren will chirp three times and indicator lights flash three times. System is set for 
sensitivity adjustment mode.  
Press the 

 

button sensitivity increase and press the 

 

button sensitivity decrease. 

Level of sensitivity indicated by number of siren chirps, there are 4 levels of sensitivity. 
To exit from sensitivity adjustment mode press the 

 

button.  

 

 
STATUS MEMORY:  

 

When the motorcycle is set into arming normal or silent mode, press the 

 

button, if 

the siren gives one extra chirp then motorcycle was tampered. 
 
 

MEMEORY FUNCTION 
 

The alarm will memorise the condition before the power is cut off. 
 
 

LEARNING TRANSMITTER CODES: 
 

This alarm system can support up to 4 remote controls. The included transmitter is pre 
programmed into the systems memory at the factory. Follow the below steps to add or 
delete a new transmitter. 
 
1. In disarming mode, ACC OFF position. Turn the ACC ON/OFF 8 times and lastly turn it 
ON, the car enters into code learning mode.

 

2. Press and hold a button on the first remote for 1 second, parking light flash once, 
siren chirp once. The first remote is learned.

 

3. Press and hold a button on the second remote for 1 second, parking light flash twice, 
siren chirp twice, indicating the second remote learned.

 

4. Follow the above procedures, the times the parking light flash or the siren chirps 
indicate the sequence of the remote learned.

 

5. Altogether 4 remotes can be learned. If the 5th remote learned, it will automatically 
replace the first one. 
 
 
 

TROUBLESHOOTING 

Can not disarm or arm the alarm system 

 

Check the alarm fuse. Check you are within range of the motorcycle (10m max). 
Check the ignition switch is in the OFF position. Check the integrity of the 
transmitter battery.  

Starter motor fails to function 

 

Check the motorcycle battery in good condition. Ensure that engine ‘Run/Stop 
switch is in the ‘run’ position, side stand is up and motorcycle is not in gear. 

 
 

 

3

3

Отзывы: