Output Adjustment Setup Menu
Sultan
Acoustic Wave Series
32
Adjust Fill Damping
0-999
Fill Damp
Output Adj
Empty Damp
4mA Adj
20mA Adj
Analog
Simulate
Comms Type
Rly Mode 1
Adjust Empty Damping
0-999
Adjust 4.00mA for remote indicator
Flip the high/low output to 4-20mA or 20-4mA
Simulate distance with 4-20mA change
Adjust 20mA for remote indicator
L1 = Relay ON dist.
L2 = Relay OFF dist
DEN
EN
FS
OFF
See Comms Types on page 31
CAL
CAL
CAL
CAL
CAL
CAL
CAL
Continues with Rly Modes 2-5 all with same menu as Rly Mode 1
CAL
CAL
RlyL1 RlyL2
CAL
Bk Light
DispChar
CAL
Switch on/off LCD backlight
CAL
Adjust number of characters per line on display 8 or 12
Press RUN twice to revert to normal operation
V in Chk
CAL
When active the unit will switch to failsafe mode if input
voltage drops below required power. When not active
unit will display ‘V fail’ but not enter failsafe mode.
35