7. Gently shake the hydraulic power pack so that the air bubbles pass into the tank.
✓
Wait a few hours until all the air bubbles are in the tank.
8. Operate the system with the hydraulic power pack 2-3x with low pressure until there is no more air in
the system.
9. Close the tank lling screw with a tightening torque of 6 + 2 Nm.
10. Vent the hydraulic system using the venting provisions on the consumer.
11. Correctly dispose of the hydraulic uid, hydraulic uid container and any cloths contaminated with
hydraulic uid.
DAMAGE
Damage to valves caused by air bubbles
The system to be connected must already be lled with hydraulic uid free of air bubbles before the
hydraulic power pack is connected. Air bubbles in the hydraulic uid cause damage to valves.
HAWE Hydraulik SE
B 6014 - 07-2021 - 1.0
21/27