20
09-2015-1.0 - D 7818/1 - EV2S-CAN
www.hawe.de | 2015
Table: User parameter input 2:
User parameters
Display
Minimum
value
Maximum
value
Description
Raw value 2
(rA)
Actual value
display
Calculated value 2
(CA)
Actual value
display
Ramp positive, up 2
(PU)
0
30,000
In 1/100 sec
Ramp positive, down 2
(Pd)
0
30,000
In 1/100 sec
Ramp negative, up 2
(nU)
0
30,000
In 1/100 sec
Ramp negative, down 2
(nd)
0
30,000
In 1/100 sec
Error below 2
(Eb)
Lower error threshold
Maximum negative 2
(An)
Target value for maximum deviation in the
negative direction
Minimum negative 2
(In)
Target value for initial deviation in the
negative direction
Minimum positive 2
(IP)
Target value for initial deviation in the
positive direction
Maximum positive 2
(AP)
Target value for maximum deviation in the
positive direction
Error above 2
(Et)
Upper error threshold
Calculated negative 2
(Cn)
-1,000
1,000
Actual value A side, per mil
Calculated positive 2
(CP)
-1,000
1,000
Actual value B side, per mil