5.2  Controlling hydraulic valves using one twin or two individual proportional solenoids for 

 

alternating operation

This mode of operation requires a remote-control potentiometer for central 

 

alignment and side recognition of two positively connected direct. switches  
SB 1 and SB 2 for solenoid coils 1 and 2

Example f:  

Controlling a proportional directional valve type PSL .. or PSV .. 
as specified in D 7700-.. 

F1  =   see example a above

P1  =   Potentiometer with fixed central alignment, 2x5 k

R  =  31V varistor, such as a Siemens SIOV-S05K25 or SIOV-S10K25   

(against radio interference or excess voltage) 

 

  

Jumpers B1 and B2 (ref. voltage 5V DC) are placed, B3 open

S1B and S2B =  directional switches are included in the control gear for  

one axle

6. Appendix 

6.1 

Installation of printed circuit module on card holder

Fit together centrepiece of card holder and one of the two side pieces

Insert support bar clamp into trapezoid groove at the back

insert conductor plate into end of all-round holding grove 

insert remaining card holder side piece

Enable

disable

Jumper
B1 + B2
closed

Power 
supply

Proportional twin 
solenoid  
or  
pair of individual 
proportional  
solenoids

Module 

 

(printed circuit)

Card holder, 

left side

Support bar 
clamp

Centrepiece

right 
side

All-round 
holding groove 
for module 
(printed circuit)

Rear trapezoid 

guide groove for 
support bar clamp

Содержание EV1M2-12/24

Страница 1: ...binets Thanks to the modular design the connections on an 8 piece pin bar are clearly arranged and easily accessible from the front The amplifier fulfill Performance Level PL d and Safety Integrity Level SIL 2 Block diagram This amplifier may be used for all HAWE proportional valves see selection table in D 7810 Ü over view With electro hydraulic remote control of PSL V directional valves as speci...

Страница 2: ...select 0 5V DC 0 10V DC or 0 15V DC Pre setting 0 5V DC Reference voltage USt 5 V DC 4 load capacity max 5 mA stabilized voltage to supply potentiometer P1 Input resistance R 200 kΩ Recommended potentiom P of 2 kΩ to 10 kΩ Ramp time rise fall tR 0 1 10 s Rampe linear Ramp linear rise time and fall time separately adjustable factory pre setting 0 1s for both minimum Enable disable input TTL compati...

Страница 3: ...WN TP5 6 test points to adjust ramp times see sect 4 2 max 1 8 mm Range for securing and moving printed circuit see also sect 6 1 1 100 mV 0 5 A for EV1M2 12 24 100 mV 0 2 A for EV1M2 24 48 Plan of terminal connections KI 1 enable disable input KI 2 solenoid Kl 3 zero Volt ground for solenoid KI 4 zero output power KI 5 zero Volt signal ground KI 6 reference input KI 7 USt stabilized voltage 5V DC...

Страница 4: ...entiometer in the middle Set ramp times td and tu to minimum turn ramp potentiometer anti clockwise until reaching the stop position Multi potentiometer 25 turns Switch on supply voltage Set Imin potentiometer to minimum current Iminoper which in accordance with the Q l or p l curve of the proportional valve corresponds to its lower desired terminal function point in operation See sect 2 3 2 for t...

Страница 5: ...DC In addition the response times of the solenoid coil become shorter and the hydraulic system there fore works more quickly For higher supply voltages i e for a EV1M2 24 48 a solenoid coil for 24V DC should be used a Amplifier Set jumber B4 and connect supply voltage to terminals 4 and 8 b Adjusting ramp rise time Connect TP5 with 5 V terminal 7 connect voltmeter between TP6 and TP3 read the requ...

Страница 6: ...ity dependant target value switch for four target values relay switch Typical example of operation Fast gear 1 K1 P1 Fast gear 2 K2 P2 Slow gear K3 P3 Stop K1 K2 K3 F1 see example a above Jumper B1 and B2 closed other jumper open Example d Operation with external target value power source from SPS CNC or PC Important Note the maximum load all owedfor the power source F1 see example a above Rx 250 ...

Страница 7: ...nterference or excess voltage Jumpers B1 and B2 ref voltage 5V DC are placed B3 open S1B and S2B directional switches are included in the control gear for one axle 6 Appendix 6 1 Installation of printed circuit module on card holder Fit together centrepiece of card holder and one of the two side pieces Insert support bar clamp into trapezoid groove at the back Insert conductor plate into end of al...

Отзывы: