Electronic amplifier type EV1M2-12/24 and EV1M2-24/48

for controlling proportional valves
modular version to be connected via bolt-type terminals, SIL 2 acc. to ISO 61508-1

D 7831/1

Electronic amplifier

November 2011-00

HAWE HydrAulik SE

STREITFELDSTR. 25 • 81673 MÜNCHEN

5

© 1993 by HAWE Hydraulik

1. General

1.1 

Brief description and block diagram

The amplifier has a very high control accuracy and can be used to control a  
proportional solenoid. 

EV1M2-12/24 from 12V DC to 24V DC and EV1 M 2-24/48 from 24V DC to 48V DC.

Main components:

Permanent voltage regulator for generating 5V DC stabilized voltage

linear ramp generator (integrator) with separate adjustment of rise and fall times
dither oscillator

Current-controlled, chopped terminal stage

Main features:

i

min

 and i

max 

standard and maximum current may be precisely adjusted by multi-gear 

potentiometer.

Dither amplitude adjustable, dither frequency either 60 or 120 Hz.

Power supply secured against incorrect pole connection
Output protected against short cut and ground
dither signal superimposed on current output

Enable/disable input (making the ramp ineffective)
Improved EMC (electromagnetic compatibiIity)
In  conjunction  with  the  card  holder  available  as  an  accessory,  this  printed  circuit 
with its compact dimensions fits conveniently on to 35 mm or 32 mm support rails in 

 

electric cabinets. Thanks to the modular design the connections on an 8-piece pin bar 

are clearly arranged and easily accessible from the front.

The amplifier fulfill Performance level Pl d and  Safety integrity level Sil 2

 

Block diagram

This amplifier may be used for all HAWE proportional valves, see selection table in D 7810 Ü (over-view). With electro-hydraulic 
remote control of PSL(V) directional valves as specified in D 7700-..., always make sure due to the twin proportional solenoids used 
for switch positions A and B that, depending on the direction of control and activation, there is an automatic, electric switchover 
to the respective solenoid, for example by a directional switch (micro-switch) in the remote control hand lever potentiometer, see 

typical circuit diagram in sect. 5.2.

B4, TP3-TP6 are only in use when a coarse adjustment of the ramp times „rise“ and/or „fall“ on 
the multi-range-potentiometers is carried out by measuring the voltage (see sect. 4.2).

TP1, TP2 test points for measuring the coil (inductive) current 100 mV 

&

 0.5 A (100 mV 

&

 0.2A) 

1

)  Values in brackets valid for 

EV1M2-24/48

u

nom.

up

down

Enable/disable

http://www.hawe.de/en/products/by-category/electronics/

Technical support

Phone: + 49 (0) 89 / 37 91 00 - 1256
E-mail: [email protected]

在此可获得其他可用语言版本:

Версии данного документа на других языках см.:

본 문서의 다른 언어 버전은 다음을 참조하십시오:

その他の言語は以下をご参照ください:

Jiné jazyky k dispozici zde:

For other languages of this document see:

Andere verfügbare Sprachen hier erhältlich:

Pour les autres langues de ce document, voir:

Il documento è disponibile in altre lingue qui:

Содержание EV1M2-12/24

Страница 1: ...binets Thanks to the modular design the connections on an 8 piece pin bar are clearly arranged and easily accessible from the front The amplifier fulfill Performance Level PL d and Safety Integrity Level SIL 2 Block diagram This amplifier may be used for all HAWE proportional valves see selection table in D 7810 Ü over view With electro hydraulic remote control of PSL V directional valves as speci...

Страница 2: ...select 0 5V DC 0 10V DC or 0 15V DC Pre setting 0 5V DC Reference voltage USt 5 V DC 4 load capacity max 5 mA stabilized voltage to supply potentiometer P1 Input resistance R 200 kΩ Recommended potentiom P of 2 kΩ to 10 kΩ Ramp time rise fall tR 0 1 10 s Rampe linear Ramp linear rise time and fall time separately adjustable factory pre setting 0 1s for both minimum Enable disable input TTL compati...

Страница 3: ...WN TP5 6 test points to adjust ramp times see sect 4 2 max 1 8 mm Range for securing and moving printed circuit see also sect 6 1 1 100 mV 0 5 A for EV1M2 12 24 100 mV 0 2 A for EV1M2 24 48 Plan of terminal connections KI 1 enable disable input KI 2 solenoid Kl 3 zero Volt ground for solenoid KI 4 zero output power KI 5 zero Volt signal ground KI 6 reference input KI 7 USt stabilized voltage 5V DC...

Страница 4: ...entiometer in the middle Set ramp times td and tu to minimum turn ramp potentiometer anti clockwise until reaching the stop position Multi potentiometer 25 turns Switch on supply voltage Set Imin potentiometer to minimum current Iminoper which in accordance with the Q l or p l curve of the proportional valve corresponds to its lower desired terminal function point in operation See sect 2 3 2 for t...

Страница 5: ...DC In addition the response times of the solenoid coil become shorter and the hydraulic system there fore works more quickly For higher supply voltages i e for a EV1M2 24 48 a solenoid coil for 24V DC should be used a Amplifier Set jumber B4 and connect supply voltage to terminals 4 and 8 b Adjusting ramp rise time Connect TP5 with 5 V terminal 7 connect voltmeter between TP6 and TP3 read the requ...

Страница 6: ...ity dependant target value switch for four target values relay switch Typical example of operation Fast gear 1 K1 P1 Fast gear 2 K2 P2 Slow gear K3 P3 Stop K1 K2 K3 F1 see example a above Jumper B1 and B2 closed other jumper open Example d Operation with external target value power source from SPS CNC or PC Important Note the maximum load all owedfor the power source F1 see example a above Rx 250 ...

Страница 7: ...nterference or excess voltage Jumpers B1 and B2 ref voltage 5V DC are placed B3 open S1B and S2B directional switches are included in the control gear for one axle 6 Appendix 6 1 Installation of printed circuit module on card holder Fit together centrepiece of card holder and one of the two side pieces Insert support bar clamp into trapezoid groove at the back Insert conductor plate into end of al...

Отзывы: