![HAWE Hydraulik DG 1 R Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/hawe-hydraulik/dg-1-r/dg-1-r_manual_2109262011.webp)
Pressure switch
DG 1..
DG 3..
Micro switch type
X 04-Z 25
XCG 3
Mechanical lifetime approx./switching cycles
10 x 10
6
10 x 10
6
For 12 V DC = 4 A and L/R = 10 ms
1 x 10
6
0.35 x 10
6
For 230 V, 1 A and cos.
9
= 0.3
A current at 230 V AC; n switching cycles
Maximum supply voltage U
max
< 50 V AC or 75 V DC
2 A
Switching current I
min
To ensure a safe contact, the current must not fall below certain minimum values:
24 V DC = I
min
= 10 mA
12 V DC = I
min
= 100 mA
Version DG 3. -X. -KB
Switching current I
min
To ensure a safe contact, the current must not fall below certain minimum values:
24 V DC = I
min
= 5 mA
12 V DC = I
min
= 100 mA
©