Symptoms

Possible Cause

PRV

Flexible Pipe Inlet/ Outlet

Improper Installation 

Suggested Remedy

Reset MCB

MCB Rating Advice :- For 3 kW-  15 A or more & For 

4.5 kW 20 A or more

Press Reset Button present in unit

Make sure Water is filled in tank before switching 

the unit again

Switch On the power supply

Check blue/red light is glowing 

Use only ISI marked 3-Pin Plug (Not provided with 

this unit) For 3 kW-  15 A or more & For 4.5 kW 20 A 

or more

Check earthing of the house

Make tight electrical connections

By Controlling flow of water, desired hot water 

can be achieved. Greater the flow, lower will be 

the temperature of water and vice versa

Advice to keep 2 L / min (to be checked & set 

through tap by customer)

If more then 20 Floor (Water Head max Height 

65 m) Recommend to use pressure reducer

Steps to follow :- Locate the Leak, Shut off Water, 

Check Fittings,  Repair or Replace (Flexipipes Not 

provided with this unit)

Installation by Havells team

Poor electrical installation

Current in Water

Water Flow Rate

Low Heating

Water Leakage

MCB has tripped

Cut-out operated

Unit does not start

NO power supply

NOTE :-

 If the Unit still does not work, or if any other types of symptoms are 

encounter, shut off the power supply and call the Havells customer service

Troubleshooting Chart