Hausted MBC Скачать руководство пользователя страница 5

MBC-IN-INS-LAB-RevC16 5

 WARNING: PERSONAL INJURY HAZARD — When the unit is in the stretcher position, DO 

NOT sit on the head or foot end of the patient surface.

 WARNING: PERSONAL INJURY HAZARD — DO NOT stand on the footrest or use it as a 

step stool. Tipping may occur.

 WARNING: Always secure patient with restraint straps when left unattended in a fully 

reclined position.

 WARNING: TIPPING HAZARD — The CPR / Surgical Support Legs should be used at any 

time when the unit is in the horizontal position, as shown in Figure 3-8.

 WARNING: It is recommended that only accessories approved by GF Health Products, Inc. 

be used with this device. The use of accessories, transducers, and cables other than those 

specified by the manufacturer may result in increased emissions or decreased immunity of 

the Hausted equipment.

2  UNCRATING INSTRUCTIONS

IMPORTANT — REPORT ANY SHIPPING DAMAGE IMMEDIATELY

 WARNING: Inform shipper of any damages — leave carton intact. Leave equipment in the 

receiving area until inspection is complete.

NOTICE — POSSIBLE EQUIPMENT DAMAGE

s

  NOTICE: This crate contains fragile, expensive medical equipment. Uncrate and handle 

carefully. If after uncrating the equipment you find any damage (no matter how slight), 

report the damage to GF Health Products, Inc.

WARNING — PERSONAL INJURY HAZARD

 WARNING: When cutting bands, always use a tool specifically designed for that purpose. 

This will help avoid personal injuries possibly incurred when bands are cut and tension is 
released.

IMPORTANT: Follow each step in the order shown in these instructions.

UNPACKING INSTRUCTIONS

Your Hausted equipment has been carefully packed at our manufacturing plant to ensure safe 
shipment to your medical facility. There are several procedures you must follow to put your new 
equipment in service. These procedures only take a few minutes to complete and all are required 
to ensure proper operation of the equipment.
1.  Cut the two bands around the shipping carton.
2.  Remove the top half of the carton and cut one side of the bottom half.
3.  Remove the equipment from the carton.
4.  Check to see if all features of the equipment work properly. If all features work, advance to step 

5. If any of the features do not work properly, call GF Health Products, Inc. at 1-770-368-4700.

5.  Clean the equipment using mild detergent to remove any dirt accumulated during shipment, 

and place the equipment into service.

Содержание MBC

Страница 1: ...MBC MAMMOGRAPHY BIOPSY CHAIR OPERATING MANUAL READ THIS MANUAL BEFORE OPERATING YOUR MBC MAMMOGRAPHY BIOPSY CHAIR SAVE THIS MANUAL FOR FUTURE USE THE MOST CURRENT VERSION OF THIS MANUAL CAN BE FOUND ONLINE AT WWW HAUSTED COM ...

Страница 2: ...KES 8 3 1 2 RELEASING THE BRAKES 8 3 1 3 APPLYING THE STEERING LOCK 8 3 1 4 RELEASING THE STEERING LOCK 8 3 2 HEIGHT AND TOP ADJUSTMENT 9 3 2 1 HEIGHT ADJUSTMENT 9 3 2 2 LOWERING THE UNIT 9 3 2 3 TOP ADJUSTMENT 9 3 2 4 TRENDELENBURG ADJUSTMENT 9 3 3 CPR SURGICAL SUPPORT LEG ACCESSORY NUMBER HAPC02500 10 3 3 1 OPERATING INSTRUCTIONS 10 CPR USE 10 STORAGE 10 4 PREVENTIVE MAINTENANCE FOR THE USER 11 ...

Страница 3: ...SERVICE INFORMATION A thorough preventive maintenance program is essential to safe and proper unit operation This manual contains maintenance schedules and procedures which should be followed for satisfactory equipment performance We encourage you to contact GF Health Products Inc with maintenance concerns ADVISORY A listing of the safety precautions to be observed when operating and servicing thi...

Страница 4: ...tion or unsafe practice that if not avoided could result in death or serious personal injury CAUTION Indicates a potential hazard situation or unsafe practice that if not avoided could result in minor or moderate personal injury s NOTICE Indicates a potential hazard situation or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations...

Страница 5: ...medical equipment Uncrate and handle carefully If after uncrating the equipment you find any damage no matter how slight report the damage to GF Health Products Inc WARNING PERSONAL INJURY HAZARD WARNING When cutting bands always use a tool specifically designed for that purpose This will help avoid personal injuries possibly incurred when bands are cut and tension is released IMPORTANT Follow eac...

Страница 6: ...enter side rail locations by lowering the side rail as shown in diagrams A and B above At no time should the patient be permitted to enter or exit from the ends of the MBC as shown on diagrams 1 2 and 3 except in a full chair position WARNING PERSONAL INJURY HAZARD When the unit is in the stretcher position DO NOT sit on the head or foot end of the patient surface WARNING PERSONAL INJURY HAZARD DO...

Страница 7: ...E to raise the backrest slightly then use TRENDELENBURG Depress for STEERING LOCK Depress for BRAKE Depress and hold to lower unit Pump to elevate FIGURE 3 2 MBC SPECIFICATIONS Height adjustment Hydraulic Backrest adjustment including 10 Trendelenburg Pneumatic Caster braking system Four wheel braking system with steering lock Dimensions Overall dimensions of patient surface Chair position Stretch...

Страница 8: ...rakes are locked when the patient is not being transported 3 1 3 Applying the Steering Lock Apply the steering lock by depressing the green pedal at patient left front downward to approximately 45 into locked position Figure 3 3 and push the unit forward One or both of the caster wheels at the opposite end will lock into a non swivelling position that enables straight tracking and swivelling by th...

Страница 9: ...fo Pedals are located on both sides of the unit When the unit reaches the desired height return the pedal to its original position s NOTICE Do not stand on the pedal 3 2 3 Top adjustment To adjust the unit anywhere from the chair position to the stretcher position grasp the RECLINE handle A adjust the unit to the desired position and release the handle See Figure 3 7 3 2 4 Trendelenburg adjustment...

Страница 10: ...just the MBC to the desired horizontal position The legs will automatically hinge into position and lock 3 Pull the knob out and allow the rack to slide until it makes contact with the floor Release the knob to engage the lock 4 Ensure the knob is locked into position by pushing down on the head end of the unit No slippage of the rack should occur 5 The legs are now ready for use ensuring rigid st...

Страница 11: ...isinfectants are the best choice for vinyl products properly diluted quaternaries are also acceptable Quaternary Isopropyl disinfectants are not recommended for vinyl Disinfectants urethane products Quaternary disinfectants are recommended for urethane products Quaternary Isopropyl disinfectants are recommended for urethane Phenolics should be avoided on urethane Disinfectants all products All fab...

Страница 12: ...in 68 cm to 137 cm 2 section with holder H06123900 Armboard with 1 in 2 5 cm pad for reclined position H06599000 Armboard with 1 in 2 5 cm pad for seated position WARNING It is recommended that only accessories approved by GF Health Products Inc be used with this device The use of accessories transducers and cables other than those specified by the manufacturer may result in increased emissions or...

Страница 13: ...nce alteration accident freight damage tampering or failure to seek and obtain repair or replacement in a timely manner 2 Products which are not properly installed used or cleaned and maintained as required in the official manual for the applicable product 3 Products considered to be of a consumable nature including but not limited to filters fuses gaskets lubricants and charts 4 Accessories or pa...

Страница 14: ...ided with a plastic types code and fiber content to aid sorting of plastic parts Product Metal Scrap Cable Scrap Electronic Scrap Plastic Recycling or Combustion MBC X X KEY TO SYMBOLS The following symbols are used on Hausted product labels Protective Earth Manufacturer Earth Ground Keep Dry General Warning Sign Fragile Handle with Care CE Mark Electrical and Electronic Equipment ETL Consult Inst...

Страница 15: ...orized Representative 3 H Height adjustment 9 I Indications for Use 3 Info statement significance 4 K Key to symbols 14 L Limited warranty 13 Lubrication 11 M Manufactured by 3 N NOTICE statement significance 4 O Operating instructions 6 S Safety statements significance of 4 Service information 3 Specifications 7 Steering lock applying 8 Steering lock releasing 8 Symbol key Hausted product labels ...

Страница 16: ...subject to change The most current and complete product information can be found on our website 2014 GF Health Products Inc All Rights Reserved Hausted and Graham Field are trademarks of GF Health Products Inc Manufactured by GF Health Products Inc ...

Отзывы: