Hauslane UC-PS18 Скачать руководство пользователя страница 3

Any defects or damage to light bulbs

Change in color or finish due to chemical usage

Improper installation not in accordance with the instructions

Dents, bumps, and scratches incurred during shipping, 
handling, or installation

Damage caused by failure to follow care and cleaning 
guidelines, including damage caused by the use of abrasive 
cleaners

Alterations made to the unit by the purchaser or installer

Damage caused by accidental impact, fire, flood, freezing, 
and normal wear

Bends and warping caused by forced connections, 
over-tightened fittings, and inadequate support during 
installation

This range hood is warranted to the original purchaser to be 
free of defects in material and workmanship for two (2) years 
from the date of purchase.
Our obligation shall be limited to the repair or replacement of 
a unit (at our discretion) that may prove, by our sole examina-
tion, to be defective under normal use and service during the 
warranty period. We may issue credit in the amount of the 
invoice value of the defective product (or a percentage of it 
according to use) in lieu of repair or replacement. Any failure 
of this product that is not traceable to a defect in material or 
workmanship is not covered by this warranty. These non-war-
rantable items include, but are not limited to:

A thorough inspection must be made before installation 
and any damage must be promptly reported. We will not 
be liable for failures or damage that could have been 
discovered or avoided by proper inspection and testing 
prior to installation.
Incidental repairs that would involve a minimum of time 
and effort on behalf of the purchaser will not be consid-
ered warranty work and no compensation will be deemed 
forth coming.
This warranty is non-transferable and shall be voided if 
the unit is removed from its initial installation or if it is not 
installed following the instructions.
Under no circumstance shall we be held liable for 
personal injury or property damage resulting from 
improper installation or use of this product. We will not 
be held liable for inconvenience caused by loss of use of 
this product, costs incurred for labor or materials, removal 
and installation of replacement units, or any other 
incidental or consequential damages. Costs relating to 
obtaining access for repair or replacement are the 
responsibility of the user.
This warranty does not extend to commercial and 
institutional installation or use.

Warranty Claim Procedure

Description of the range hood

Proof of sale

Details regarding the defect

Name(s) and address(es) of the owner and installer

If a claimable defect occurs, please contact our customer 
service team at 1-800-929-0168 (8 a.m. - 5 p.m., PST, 
Monday - Friday). or email us at [email protected]
Before you make your claim call, please ensure that you 
have: 

Claims must be filled out in writing and returned within six 
(6) months of the appearance of a defect. Failure to
comply with this stipulation will make this warranty null
and void. We reserve the right to a thirty-day (30) delay
following the receipt of a claim in which to inspect the
product. We assume no responsibility for labor costs,
removing or replacing a previously installed product,
transportation, or the return of a product.

Warranty Information

1.

2.

3.

For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.

To avoid damage and noisy and/or unbalanced impellers,
keep drywall/construction dust, etc. off power unit.

Mount your range hood so that the bottom of the hood is
24" to 30" above the cooking surface. The minimum hood
distance above cooktop must not be less than 24"; any
installation less than 24" may cause overheating and cause
damage to the range hood, HAUSLANE does not warrant
this improper installation.

4.

5.

6.

7.

8.

Two to three installers are recommended because of 
the larger size and weight of this hood.

To reduce the risk of fire and to properly exhaust air, be 
sure to duct air outside. Do not exhaust air into spaces 
within walls and ceiling or into attics, crawl space or 
garages.

Because of the high exhausting capacity of this hood, 
you should make sure enough air is entering the house 
to replace exhausted air by opening a window close to 
or in the kitchen.

Use with approved cord-connection kit only.

Please read product specification label on range hood 
for further information and requirements.

CAUTION

UC-PS18 USER MANUAL

3

C. The fire department has been called.
D. You can fight the fire with your back to an exit.

*Based on "Kitchen Fire Safety Tips" published by NFPA.

Содержание UC-PS18

Страница 1: ...USER MANUAL HAUSLANE Kitchen Range Hood Models UC PS18 30 UC PS18 36 ...

Страница 2: ...roper combustion and exhaust ing of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting ...

Страница 3: ...lation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility of the user This warranty does not extend to commercial and institutional installation or use Warranty Claim Procedure Description of the range hood Proof of sale Details regarding the defect Name s and address es of the owner and installe...

Страница 4: ...led 5 4 3 2 1 Electric Drill Extended length head driver bit Safety Gloves Pencil Flathead Screwdriver Philips Screwdriver 13 12 11 Safety Goggles Measuring Tape Aluminum Foil Tape 10 9 8 7 6 Keyhole Saw 1 Utitlity Knife Level Adjustable Wrench Needle Nose Pliers 1 2 3 4 5 6 9 10 11 12 13 7 8 UC PS18 USER MANUAL 4 1 2 3 9 4 6 7 8 10 11 Specifications Volts Hertz Fan CFM Speeds Light Wattage Stainl...

Страница 5: ... domestic power supply to guarantee adequate earthing before installation This range hood must be ducted to the outside Don t connect the range hood to exhaust ducts that carry any type of combustion fumes like fireplaces boilers or any similar items The vents should have a short straight run to the outside Avoid any elbows if possible and if an elbow is required a minimum of a 12 straight run is ...

Страница 6: ... from the damper will cause reduction in performance Make sure to install with the existing black rubber gasket Is it a horizontal rectangular duct If so remove existing round adapter by removing the 10 screws Cover the opening with the shutoff plate and secure with 10 screws This renders the round duct opening useless and you can move forward with the installation of proper arrangements for horiz...

Страница 7: ...ched atbackcornerto allowplugclrearance 2 Cabinet or soffit with flush bottom 30 cabinet typical Cabinetwith flushbottom 12 typical CL 1 1 4 2 1 hole 4 1 8 8 1 4 2 1 2 2 3 8 3 1 4 1 7 8 Four 4 mountingholes 2 1 10 1 2 x3 3 4 hole 15 Four 4 mounting holes Cabinet with recessed bottom 30 cabinet typical Cabinetwith recessedbottom 12 typical 10 1 2 x3 3 4 hole CL 1 1 4 2 1 hole 4 1 8 15 1 3 1 2 widef...

Страница 8: ...es 8 1 4 2 1 2 2 3 8 2 Cabinet with recessed bottom 30 cabinet typical Cabinetwith recessedbottom 10 1 2 x3 3 4 hole CL 15 2 3 8 1 1 4 2 1 hole Four 4 mountingholes 3 1 4 1 7 8 Four 4 mountingholes 1 8 1 4 2 1 2 2 3 8 2 Cabinet with flush bottom 30 cabinet typical Cabinetwith flushbottom 10 1 2 x3 3 4 hole CL 15 2 3 8 1 1 4 2 1 hole 3 Rectangular Horizontal Adapter ...

Страница 9: ... x3 3 4 hole Cabinet with recessed bottom 36 cabinet typical Cabinetwith recessedbottom 12 typical 10 1 2 x3 3 4 hole CL 4 1 8 15 1 2 UC PS18 36 1 Round Vertical Adapter 2 Rectangular Vertical Adapter Four 4 mounting holes 6 1 2 widefiller alongfront andsides RHfillernotched atbackcornerto allowplugclrearance 3 1 4 4 1 8 8 1 4 2 1 2 5 1 2 Four 4 mountingholes 3 1 4 4 1 8 8 1 4 2 1 2 5 1 2 Four 4 m...

Страница 10: ...fillernotched atbackcornerto allowplugclrearance 1 2 Cabinet with recessed bottom 36 cabinet typical Cabinetwith recessedbottom 10 1 2 x3 3 4 hole CL 18 2 3 8 Four 4 mountingholes 1 2 Cabinet with flush bottom 36 cabinet typical Cabinetwith flushbottom 10 1 2 x3 3 4 hole CL 18 2 3 8 3 Rectangular Horizontal Adapter 3 1 4 4 1 8 8 1 4 2 1 2 5 1 2 ...

Страница 11: ...each the rear mounting holes use an extension tool for the power drill 3 Jack Up the Hood If you are not removing the range place the plywood 30 x 24 over the range cooktop to avoid possible damage Put the cabinet jacks on the plywood and place the second piece of plywood over the two cabinet jacks Using the cabinet jacks lift the hood into its position under the cabinet Ensure that the adapter an...

Страница 12: ...ow that your range hood is installed it s time to learn how to use it It is very simple to use and is operated entirely using the front control panel How to Turn Light On Off This range hood has a single light setting Press the lightbulb button 2 to turn the light on or off CAUTION For halogen lamps never touch bulbs during operation they can get very hot How to Set the Fan Speed Press the on off ...

Страница 13: ... into the socket and rotate Cleaning Your Range Hood This range hood will look great and function correctly for a long time with proper care Here are a few do s and dont s when caring for your range hood WARNING Failure to maintain basic standards of care and cleaning will increase the risk of fire Clean the range hood with warm soapy cloth or a stainless steel polish Clean the hood in line with t...

Страница 14: ...TOR AC 12V M C M C BLUE RED BROWN BLUE BLACK RED BROWN BLUE BLACK BLACK WHITE WHITE BLACK YELLOW WHITE YELLOW YELLOW GREEN YELLOW GREEN WHITE GREEN RED BLACK RED BROWN AMP POWER ELECTRIC SWITCH CONTROL PANEL UC PS18 USER MANUAL 14 ...

Страница 15: ...lves the issue 3 If replacement and or tightening does not solve you may need to replace the lighting service system on the hood The touch panel is not responding 1 Perform a power cycle reset by unplug the power cord wait 10 seconds and plug the power cord back 2 If Step 1 doesn t resolve the issue please contact us immediately for a control panel replacement Still experiencing problems after fol...

Страница 16: ...ite at www hauslane com Parts and Accessories If you need replacement parts or accessories visit www hauslane com Contact Us We d be happy to answer your questions or resolve any issues you may have Phone 1 800 929 0168 Find Us and Connect with Us Contact Hauslane UC PS18 USER MANUAL 16 ...

Отзывы: