38
Art. Nr.: 5090032065
Rev.: 03/2018-09-25
MSH Basic-FUBO-E-SR4 / MSH Basic-MBK-R4
EN
Fig.: 28
7
Introduce individual sealing elements and gas building
entry into the MSH Basic-MBK-R4 seal insert.
Then tighten the fl aps of the sealing element with the
plastic tapping screws until they are fl ush with the inner
plate of the MSH or a torque of
14 Nm
has been reached
(see Fig.: 28).
IMPORTANT!
No sealing due to incorrect preparation of
installation!
Incorrect preparation can result in damage.
• All four sealing elements must be installed, even if
only some of the media channels are to be used.
• If no gas fi tting is to be installed for the time
being, a blind sealing element must be fi tted.
►
Fully assembled MSH Basic-MBK-R4 seal insert (see
Fig.: 29).
Fig.: 29
6
If a gas fi tting is to be installed, the pre-assembled sec-
ondary sealing element must be spread suffi ciently with
GMT or GML lubricant (see Fig.: 27).
Legend for Fig.: 27
1
Secondary sealing element
AFig: 27
1