HAUBER-Elektronik GmbH
17
16
Transport, storage and disposal
The sensor must be protected from damaging environmental factors and mechanical damage
during transport with the use of adequate packing.
The sensor may not be stored in ambient temperatures outside the permitted operating
temperature.
The product contains electronic components and must be disposed of properly in accordance
with local laws and regulations.
17
Coding HE050
HE050. 0.
1.
0.
001
HE series
050 = IO link sensor
Certifications
0 = CE / IEC / cULus / EAC
1 = CE / IEC / cULus / EAC + SIL 1
IO link
0 = Configuration only ex works: Transmitter / switching contacts
1 = IO link (output 1): Transmitter / switching contacts
Housing
0 = 1.4305 (V2A) with fastening M8 x 8 mm; incline 1.25 (Standard)
1 = 1.4404 (V4A) with fastening M8 x 8 mm; incline 1.25 mm
2 = 1.4462 duplex stainless steel with fastening M8 x 8 mm; incline 1.25 mm
Software parameter settings (factory default)
Output 1
Output 2
001 =
-
-
002 =
-
4-20 mA ~ 0-16 mm/s, rms; 10 Hz-1000 Hz
003 =
-
4-20 mA ~ 0-25 mm/s, rms; 10 Hz-1000 Hz
004 =
-
4-20 mA ~ 0-32 mm/s, rms; 10 Hz-1000 Hz
005 =
-
4-20 mA ~ 0-50 mm/s, rms; 10 Hz-1000 Hz
006 =
-
4-20 mA ~ 0-64 mm/s, rms; 10 Hz-1000 Hz
Don’t see your desired configuration listed? Please contact
us and we can offer you a solution for your specific needs.