background image

 

 

Betriebsanleitung 

englisch 

Doc ID: M001-HE050 Stand: 2021-06-09 

 

 

 

 

 

 

 

 

Vibration monitoring unit 
Series HE050 

 

 

 
• 

Vibration velocity (mm/s, rms) 

• 

Vibration acceleration (g, rms) 

• 

Vibration acceleration (g, rms) 

• 

Temperature (°C) 

• 

Output 1: IO-Link or 
                Digital switching output 

• 

Output 2: Analogue current output 4…20 mA or 
                Digital switching output 

• 

Adjustable frequency range: 10 Hz … 1000 Hz 

Date of manufacture: 

 

 

Type description: 

 

 

Serial no.: 

 

 

 

 

 

 

Содержание HE050 Series

Страница 1: ... Vibration velocity mm s rms Vibration acceleration g rms Vibration acceleration g rms Temperature C Output 1 IO Link or Digital switching output Output 2 Analogue current output 4 20 mA or Digital switching output Adjustable frequency range 10 Hz 1000 Hz Date of manufacture Type description Serial no ...

Страница 2: ...he product the instruction manual must be read and understood All rights reserved including rights to translation Subject to modifications Please contact the company with any questions HAUBER Elektronik GmbH Fabrikstraße 6 D 72622 Nürtingen Germany Tel 49 0 7022 21750 0 Fax 49 0 7022 21750 50 info hauber elektronik de www hauber elektronik de ...

Страница 3: ...ensions 11 11 Connection 11 12 IO Link description of functionality 12 12 1 Introduction 12 12 2 Software parameterization service 12 12 3 General data 12 12 4 Measured values and process values 12 12 5 Outputs 12 12 6 Switching signals 13 12 7 Frequency ranges Filter settings 13 12 8 Maintenance Data 13 13 Installation and commissioning 14 13 1 General notes 14 13 2 Wiring diagram earthing concep...

Страница 4: ...obtained in other languages The product is built according to the latest state of the art However hazards to people machinery and systems can still arise as the result of improper handling unintended use or operation and maintenance by persons inadequately trained on the product All those who are involved in the installation operation and maintenance of the product in the operator s plant must rea...

Страница 5: ...y level SIL1 5 Intended use The HE050 type is used exclusively for measuring mechanical vibrations and the temperature in machines and mechanical systems Its use is only permissible within the specifications stated in the data sheet Main fields of application Fans ventilators blowers electric motors pumps centrifuges separators generators turbines and similar oscillating mechanical systems If the ...

Страница 6: ...dard the following information must be observed Electrical protection Devices must be protected by means of fuses circuit breakers overheating protection impedance limiting switches or similar to ensure protection against excessive power output if there is a fault in the device Protection must be applied to supply lines and switching lines A circuit breaker suitable for 30V 3A according to UL Stan...

Страница 7: ...rs MTTF years Tab 1 General data 10 2 Electrical data Voltage supply 24 V DC 10 Current supply max 250 mA Output 1 Pin 4 Output signal 4 20 mA proportional to the measuring range Apparent ohmic resistance load max 500 Ω Switching outputs Output signal Digital I O Electrical execution PNP NPN configurable Output function Normally closed normally open low active high active Switching levels 0 V Low ...

Страница 8: ... 𝑣𝑚𝑎𝑥 𝑎𝑚𝑎𝑥 2𝜋𝑓 Fig 1 shows the operating range of the vibration monitoring unit which is limited by the maximum measurable vibration velocity in mm s depending on the frequency in Hz Fig 1 Operating range diagram 1 Frequency in Hz 2 Vibration velocity in mm s rms 3 Operating range of the vibration monitoring unit Reading examples Frequency Hz Maximum measurable Vibration velocity mm s rms 250 93 6...

Страница 9: ... 4 Typical frequency response 10 Hz to 1 000 Hz The frequency response is recorded using a reference sensor 4 Hz 1 200 Hz acceleration sensor Fig 2 Typical frequency response 10 Hz 1 000 Hz 1 Frequency in Hz 2 Amplification in dB ...

Страница 10: ...M8 x 8 mm Incline 1 25 mm standard Assembly type Standing vertical or lying horizontal Measurement direction Along the fixing axis Max torque of the Sensor 8 Nm Max torque of the M12 union nut on the connector 0 4 Nm Weight ca 90 g Protection class Plug connection closed IP 66 67 Type 4X Enclosure Product is suitable for outdoor applications Ambient temperature TA 40 C TA 85 C Max humidity 100 Tab...

Страница 11: ... with M12 connector All dimensions in mm 1 M12 connector 2 Width A F 24 3 Fixing 4 Measuring direction along the fixing axis 11 Connection Plug M12 4 pole Pin 1 L 24 V DC Pin 2 Out 2 4 20 mA or switching output Pin 3 L 0V GND Pin 4 Out 1 IO Link or switching output ...

Страница 12: ...ge 2020 All parameters and adresses are listed comprehensively within the IO Link description file available in the download section of our homepage This chapter only serves as an overview of the products functions 12 4 Measured values and process values Following measured values and process values can be monitored via IO Link continuously Effective value vibration velocity 0 01 mm s rms Effective...

Страница 13: ... the limit value Set to 2 by default and only adjustable with the temperature measurement 0 K 20 K 12 7 Frequency ranges Filter settings Four predefined frequency ranges can be selected 0 10 Hz 1000 Hz 1 10 Hz 500 Hz 2 10 Hz 100 Hz 3 10 Hz 50 Hz 12 8 Maintenance Data Following data is available exclusively via IO Link and cannot be output via any other output Counter It is possible to set a third ...

Страница 14: ...ps are amongst the most common problems in measurement set ups with sensitive sensor technology These issues arise due to unintentional differences in potential in the electrical circuit between the sensor and evaluation unit Ensure that the earth connection is electrically secure According to the earthing concept the cable shielding is electrically connected to the sensor housing through the knur...

Страница 15: ...ce Tool 24 mm wrench Work steps and instructions Screw vibration monitoring unit into the threaded hole of the mounting surface in a friction locked manner using a hex key The tightening torque should be 8 Nm The tightening torque of the M12 union nut of the plug connection must not exceed 0 4 Nm To obtain precise measurement values the vibration monitoring unit must be fixed to the mounting surfa...

Страница 16: ...rce and or supply Analogue signal disabled Enable analogue signal Discontinuity in connecting cable Replace connecting cable Fuse defective Replace fuse Connection has incorrect polarity Connection of correct pole Vibration monitoring unit defective Replace vibration monitoring unit Relay does not switch Wrong limit value set Set correct limit value No power supply Check power source and or supply...

Страница 17: ...IEC cULus EAC SIL 1 IO link 0 Configuration only ex works Transmitter switching contacts 1 IO link output 1 Transmitter switching contacts Housing 0 1 4305 V2A with fastening M8 x 8 mm incline 1 25 Standard 1 1 4404 V4A with fastening M8 x 8 mm incline 1 25 mm 2 1 4462 duplex stainless steel with fastening M8 x 8 mm incline 1 25 mm Software parameter settings factory default Output 1 Output 2 001 ...

Страница 18: ...ow that relate to this declaration meet the basic health and safety requirements of the norms and directives below Product series HE050 HE055 Norms and directives EU Directive Norms 2014 30 EU EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 2014 34 EU EN 60079 0 2019 EN 60079 1 2014 EN 60079 11 2012 EN 60079 31 2014 Signature Nürtingen 15 04 2021 Place and date _______________________________ Tobias B...