Hatteland HT 405P4 STD Скачать руководство пользователя страница 12

12

IND100210-1

INB100029-1 (Rev 5)

Installation

Installation and mounting of computers

1.

  

Most of our units are intended for various methods of installation or mounting (rack mounting, panel mounting,

 

bracket mounting, ceiling/wall mounting); for details, please see the relevant mechanical drawings.

2.

  

Adequate ventilation is a necessary prerequisite for the life of the unit. The air inlet and outlet openings must

 

definitely be kept clear; coverings which restrict ventilation are not permissible. The product might be without

             any ventilation aperatures which means pt.2 does not apply.

.

  

Exposure to direct sunlight can cause a considerable increase in the temperature of the unit, and might under

 

certain circumstances lead to overtemperature. This point should already be taken into consideration when

 

the bridge equipment is being planned (sun shades, distance from the windows, ventilation, etc.)

4.

  

Space necessary for ventilation, for cable inlets, for the operating procedures and for maintenance, must be

 

provided.

5.

  

To further improve the cooling of the unit we recommend installing Cooling Fans underneath blowing upwards

 

into the unit air inlet. This may be required in high temperature applications and also when there is reason to

 

expect temperature problems due to non-optimal way of mounting.

General mounting instructions

1. 

 

The useful life of the components of all Electronics Units generally decreases with increasing ambient

 

temperature; it is therefore advisable to install such units in air-conditioned rooms. If there are no such

 

facilities, these rooms must at least be dry, adequately ventilated and kept at a suitable temperature in order

 

to prevent the formation of condensation inside the unit.

2. 

 

With most Electronic Units, cooling takes place via the surface of the casing. The cooling must not be

 

impaired by partial covering of the unit or by installation of the unit in a confined cabinet.

 

In the area of the wheel house, the distance of each electronics unit from the magnetic standard compass or

 

the magnetic steering compass must not be less than the permitted magnetic protection distance. This

 

distance is measured from the centre of the magnetic system of the compass to the nearest point on the

 

corresponding unit concerned. The exact distance is often mentioned in the specific product specifications.

4.

  

Transportation damage, even if apparently insignificant at first glance, must immediately be examined and be

 

reported to the freight carrier. The moment of setting-to-work of the equipment is too late, not only for

 

reporting the  damage but also for the supply of replacements.

Cables

Use only high quality shielded signal cables. For RGB/DVI cables use only cables with separate coax for Red, Green 

and Blue. We can supply a varity of high quality RGB/DVI, RS232, PARALLEL, LAN and USB cables intended for this

use.

Ferrites

On selected products, the ferrites prevent high frequency electrical noise (radio frequency interference) from exiting 

or entering the equipment. To verify if your product require this, please see the “Physical Overview” chapter in this 

manual. The ferrites are part of the contents of the package also specified in the “Contents Of Package” chapter early 

in this manual. 

The ferrites must be mounted on specific cables to fully comply with the Type Approvals!

The ferrites should be mounted (clipped in place on the cable as shown in illustration) as close as possible to

the cable connector on the rear side of the computer product. Open up the ferrite, place the cable inside

as shown in FIG1, and then gently close it until a click can be heard (FIG2). 

General Installation Recommendations

FIG1

FIG2

    To computer

    To computer

Содержание HT 405P4 STD

Страница 1: ...2007 Doc Id INB100029 1 Rev 6 For models A1 Slim User Manual Jakob Hatteland Display AS msosen N 5578 Nedre Vats Norway Tel 47 5276 3700 Fax 47 5276 5444 e mail jhd no hatteland com U S E R M A N U A...

Страница 2: ...ent of Jakob Hatteland Display AS The products described or referenced herein are copyrighted to the respective owners The products may not be copied or duplicated in any way This documentation contai...

Страница 3: ...11 Installation and mounting of computers 12 Cables 12 Ferrites 12 Operation 13 Physical Overview HT 405P4 STD 14 Specifications 15 Specifications HT 405P4 STD 16 Technical Drawings 17 Technical Draw...

Страница 4: ...l Slim version Note The separate documentation for third party components may be available on attached CD The printed manual only covers specific information for Hatteland products and not third party...

Страница 5: ...INB100029 1 Rev 5 General...

Страница 6: ...intelligence of the product The extreme small form factor used on this product line with a general depth of only 75mm and for example for the 19in with 416 W x 372 H mm allows new builds and retrofit...

Страница 7: ...e or pending Flexible display solutions and night vision facilities All JHD Type Approved displays panel computers and marine computers provide maximum flexibility for customer applications JHD offers...

Страница 8: ...IND100209 1 INB100029 1 Rev 5 General Basic Construction Rack Computers Chassis Basic Construction Mainboard Fans Harddrive Removable Harddrive Peripheral PCI AGP cards Memory CD ROM Floppy...

Страница 9: ...Cabinet Version Rack Size 2U 4U etc Hatteland Display manufacturer Product Labels Example Serial Number Label Warranty Label If you are to perform service on a unit still under warranty any warranty...

Страница 10: ...10 INB100029 1 Rev 5...

Страница 11: ...11 INB100029 1 Rev 5 Installation...

Страница 12: ...nits cooling takes place via the surface of the casing The cooling must not be impaired by partial covering of the unit or by installation of the unit in a confined cabinet 3 In the area of the wheel...

Страница 13: ...13 INB100029 1 Rev 5 Operation...

Страница 14: ...optional bracket PCIe x16 Slot 1 not connected or in use Hatch Keylock USB 4 5 Power Switch Floppy Drive 2 5 Bay Reset Button CD ROM 3 5 Bay Alarm LED Fan LED S2 LED Power LED Harddrive LED S1 LED Ai...

Страница 15: ...15 INB100029 1 Rev 5 Specifications...

Страница 16: ...ress Based 2 x RJ 45 USB Ports 6 x USB 2 0 4 in back 2 in front 6 x USB Keyboard Port 1 x Standard PS 2 mini DIN connector 1 x PS 2 Mouse Port 1 x Standard PS 2 mini DIN connector 1 x PS 2 Audio ICH6...

Страница 17: ...17 INB100029 1 Rev 5 Technical Drawings...

Страница 18: ...cal Drawings HT 405P4 STD Standard Version Due to dimensions without decimals the tolerance on drawings is 1mm For accurate measurements measure in AutoCAD Technical drawings DWG format are found on o...

Страница 19: ...ical Drawings HT 405P4 STD Slide Mounting Due to dimensions without decimals the tolerance on drawings is 1mm For accurate measurements measure in AutoCAD Technical drawings DWG format are found on ou...

Страница 20: ...20 INB100029 1 Rev 5...

Страница 21: ...21 INB100029 1 Rev 5 Appendixes...

Страница 22: ...2 3 4 5 6 7 8 Note Not all connectors may be available on your specific product This depends on the amount of additional hardware installed from factory or customized solutions These pin assignments...

Страница 23: ...ND Ground 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 Pin Assignments 24P DVI D DVI I Pin 01 T M D S Data2 Digital RED link 1 Pin 02 T M D S Data2 Digital RED link 1 Pin 03 T M D...

Страница 24: ...5 4 3 2 1 9 8 7 6 Pin Assignments Common Connectors Additional Note These pin assignments applies for products with customer specified COM ports factory setup These COM ports are configurable on the m...

Страница 25: ...n the graphics line that may be affecting the signal such as a signal splitter please note that normally a signal splitter will not have any adverse effect If it is impossible to change to the correct...

Страница 26: ...ce sales department if additional questions Current prices apply as per May 2004 Signal Cable DSUB 15P Male or Female Approx 1 8meters Price 170 NOK each Signal Cable BNC 5P Approx 1 8meters Price 350...

Страница 27: ...hase price additional interests and charges have been paid in full Accepted bill is not considered as payment until it has been honoured in full 6 TIME OF DELIVERY The quoted time of delivery is based...

Страница 28: ...is charged Returned goods are shipped on customer s account and risk 13 LOAN RENT and DEMO When borrowing of goods for demo test the date of return must be added to the document If no date has been st...

Страница 29: ...l or on the driving slip 3 RESCUE Bound the damage Try to restrict the damage and the loss Seller will compensate expences incurred due to reasonable security efforts in addition to damage and loss 4...

Страница 30: ...g a wrist band 2 The wrist band should be connected to ground via a ground cord 3 A one megaohm resistor installed in the wrist connection end of the ground cord is a safety requirement 4 Alternativel...

Страница 31: ...31 IND100077 24 INB100029 1 Rev 5 Appendix Notes...

Страница 32: ...RS485 pin assignments chapter and specifications 3 SE 22 Aug 06 Type approval page removed and information merged with the respective product specification pages 4 SE 02 Jan 07 Revised specifications...

Страница 33: ...33 Appendix IND100213 8 INB100029 1 Rev 5...

Страница 34: ...34 Appendix IND100213 8 INB100029 1 Rev 5...

Страница 35: ...35 Appendix IND100213 8 INB100029 1 Rev 5...

Страница 36: ...Sales office Frankfurt Germany Jakob Hatteland Display GmbH Werner Heisenberg Strasse 12 D 63263 Neu Isenburg Germany Tel 49 6102 370 954 Fax 49 6102 370 968 Sales office Aix en Provence France Jakob...

Отзывы: