General Installation Recommendations
Installation
IND100210-14
If your installation require additional cable fasteners support, please visit and purchase directly from manufacturer:
Illustrations below are approximate, actual Housing and Hood may deviate slightly, but function remains the same.
Phoenix Cable Housing - Illustration
Weidmüller Cover Hood - Illustration
Phoenix 1803934 - KGG-MSTB 2,5/ 2 (2-pin)
Phoenix 1834372 - KGG-MC 1,5/ 5 (5-pin)
Weidmüller 1005290000 - BCZ 3.81 AH04 BK BX (4-pin)
Weidmüller 1005300000 - BCZ 3.81 AH05 BK BX (5-pin)
For Phoenix 2-pin and 5-pin:
https://www.phoenixcontact.com/online/portal/us?uri=pxc-oc-itemdetail:pid=1803934&library=usen&pcck=P-11-02-01&tab=1
https://www.phoenixcontact.com/online/portal/us?uri=pxc-oc-itemdetail:pid=1834372&library=usen&pcck=P-11-02-01&tab=1
For Weidmüller 4-pin and 5-pin
http://catalog.weidmueller.com/procat/Product.jsp;jsessionid=B040D5EB6832629E567C884809FDF6C1?productId=(%5b1005290000%5d)
http://catalog.weidmueller.com/procat/Product.jsp;jsessionid=D399022A1B3211C0146BCBE716D93211?productId=(%5b1005300000%5d)
Configuring Housing / Terminal Block connectors
Below is a brief illustration that might be useful during configuration and installation of such connectors. You will need
suitable pre-configured cable(s) and tools to configure the connector(s) and cable(s) that are present in your
installation environment. Below is a sample procedure for a 2-pin DC power connector. The procedure is the same for
other connectors of this type as listed in table above. Unit used as illustration below is for reference only.
FIG 3
FIG 1
FIG 2
FIG 4
FIG 1:
Unscrew (from top) or make sure that the screw terminal (square area) are fully open, so you can secure the
inserted cables correctly to the loose housing connector (it may already be plugged into the unit as per factory
installation).
FIG 2:
Insert cables* (from front) and screw / secure the cables by turning the screw on top of the housing to secure
the cables properly. Check that the cables is firmly in place and do not appear loose or falls out when pulling gently.
*Note: Required polarization verification (for instance -/+ for DC power input) should conform with the markings on
the connector area of the unit. Ignoring the markings on the unit or its add-on modules might damage the unit and/or
external equipment in which end, warranty will be void.
FIG 3:
Plug the housing into the appropriate connector area of the unit (glass should be facing down) and check again
that the cables secured conforms with the markings on the connector area of the unit. Finalize the installation by
fasten the screws located in front on each side of the housing connector
(FIG 4).
Содержание HD 08T21 STD-***-F SERIES
Страница 6: ...6 This page left intentionally blank...
Страница 7: ...7 General...
Страница 15: ...15 Installation...
Страница 26: ...26 This page left intentionally blank...
Страница 27: ...27 Operation...
Страница 31: ...31 Specifications...
Страница 34: ...34 This page left intentionally blank...
Страница 35: ...35 Technical Drawings...
Страница 38: ...38 This page left intentionally blank...
Страница 39: ...39 Appendixes...
Страница 47: ...47 Appendix IND100077 24 User Notes...
Страница 49: ...49 Revision History Appendix IND100077 120...
Страница 50: ...www hatteland display com...