Hathor Energy HATHOR-16TM Скачать руководство пользователя страница 7

7

HATHOR

DAILY WEEKLY TIMER WITH 

PHOTO SENSOR

HATHOR-16TM SERVICE MANUAL

1 – green LED indicates the “ON” state of relay;
2 – green/red LED signal indicates the input voltage presence;
3 – light sensor (photodiode);
4 – menu control buttons:

– entry into menu, parameter input;
– save the parameter and menu exit;
– scrolling buttons;

5, 8 – wiring terminals;
6 – seven-segment indicator (display);
7 – green LEDs to indicate the operation mode of the relay;
9 – strap of internal accumulator (set at the use of relay), during storage to
take off a strap.

FIGURE 1. Controls description and dimension diagrams

[email protected] 

www.hathorenergy.com

Содержание HATHOR-16TM

Страница 1: ...HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM 1 info hathorenergy com www hathorenergy com...

Страница 2: ...age variations in the mains with subsequent automatic re energizing after the mains parameters recovery Load energizing de energizing in accordance with the user set illumination intensity levels The...

Страница 3: ...diode connection is also possible The HATHOR 16TM relay output terminals can immediately switch wattage load of up to 3 5 kW 16A When it is necessary to switch greater wattage a magnetic starter shou...

Страница 4: ...ting the time of load cutoff tripping based on the lower voltage threshold Setting the time of load cutoff tripping after the mains parameters recovery Setting the illumination threshold In case of ma...

Страница 5: ...unallowable voltage fluctuations are detected When the voltage returns back to normal parameters the device will automatically turn ON the power load equipment with the user defined time delay Turn ON...

Страница 6: ...fferent independent sets of parameters SP1 SP2 and may delete any of these sets if necessary Thus the client may save in the device memory 2 different settings for curtain cases Output terminals of th...

Страница 7: ...menu control buttons entry into menu parameter input save the parameter and menu exit scrolling buttons 5 8 wiring terminals 6 seven segment indicator display 7 green LEDs to indicate the operation m...

Страница 8: ...8 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL 2 TECHNICAL PARAMETERS info hathorenergy com www hathorenergy com...

Страница 9: ...R 16TM detects the unallowable OVER UNDER voltage then it will turn OFF the power load by opening the contacts 3 4 and in case of using the contactor that will turn OFF the power for the magnetic coil...

Страница 10: ...e user may keep in the device memory to choose one of the available set of parameters SP1 or SP2 to clear delete current set of parameters PARAMETER SETTINGS to view the events parameters preprogramme...

Страница 11: ...hedule of the HATHOR 16TM So after the normalization of the voltage parameters power load will be turned ON again but according to the time schedule preset by the user If mains voltage was absent not...

Страница 12: ...y start up procedures include the following steps setting of the current time and the day of a week setting the schedule of events exact time values and days of a week when the power load should be tu...

Страница 13: ...o the HATHOR 16TM it s necessary to connect mains voltage wires to 1 1 and 2 2 input contact terminals ATTENTION All connections of terminals should be performed strictly according to safety regulatio...

Страница 14: ...ts for HATHOR 16TM it s necessary to connect the power load to the output contacts of HATHOR 16TM ATTENTION In order to prevent possible electric shock all the connections of the power load should be...

Страница 15: ...15 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 16: ...16 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 17: ...17 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 18: ...18 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 19: ...19 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 20: ...20 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 21: ...21 HATHOR DAILY WEEKLY TIMER WITH PHOTO SENSOR HATHOR 16TM SERVICE MANUAL info hathorenergy com www hathorenergy com...

Страница 22: ...the settings doesn t change so when viewing them on the display there will be shown all settings made those that are valid and the deleted not active events settings also To set the time schedule for...

Страница 23: ...THE POWER LOAD IS LESS THEN 16A 3 5 KW THE RELAY MAY OPERATE WITH THE LOAD DIRECTLY VARIANT B IF THE POWER LOAD IS MORE THEN 16A 3 5 KW THE RELAY MUST OPERATE WITH THE POWER LOAD USING THE ADDITIONAL...

Страница 24: ...ATHOR 16TM in manufacturer package should be stored in enclosed rooms at from 45 to 75 C and exposed to no more than 80 of relative humidity when there are no fumes in the air that exert a deleterious...

Страница 25: ...25 info hathorenergy com www hathorenergy com...

Отзывы: