Under Mount using Mounting Studs

  1.  Carefully measure and cut the opening in the countertop. 

Use the “Under Mount Countertop Opening Dimensions” 

below as a guide.

22-7/8″

(580 mm)

14-7/8″

(377 mm)

Countertop

Countertop

9″

(229 mm) 

9″

(229 mm) 

15”

(382 mm)

15″

(382 mm)

6”x8-32

Weld

Studs

6″x8-32

Weld

Studs

Mounting Stud Installation Dimensions

  2.  Locate mounting studs on the underside of countertop.
  3. Cut and drill the appropriate holes in the vertical surface 

where the control will be installed. Refer to the “Installing the 

Control Panel” procedure for cutout dimensions.

  4.  Cut the required openings in the cabinetry to provide proper 

ventilation to the induction dry well. Refer to the “Ventilation 

Requirements” listed previously in this section.

  5.  If necessary, make structural modifications or add bracing 

underneath the countertop to ensure the countertop will 

support the weight of the unit and its contents.

  6.  Secure the unit to the underside of the countertop.

NOTE: Silicone sealant must be rated for use at temperatures 

up to 250°F (121°C).

 

a. Apply silicone sealant to the top edge of the well.

 

b. Secure the unit to the countertop by using mounting nuts 

onto mounting studs through the three holes on both 

sides of the unit.

NOTE: The countertop must be level to ensure proper operation 

of the Induction Dry Well.

Countertop

Mounting Nut

(not supplied)

Mounting

Stud

(not supplied)

Mounting Stud Installation

NOTE: The silicone sealant must be rated for use at 

 

temperatures up to 250°F (121°C).

  7.  Install the control panel. Refer to the “Installing the Control 

Panel” procedure.

Installing the Control Panel

Use the following procedure to install the control panel.

WARNING

Remote mounted control panel must be mounted on a 

vertical wall and installed in vertical position. Mounting 

control panel in horizontal position may result in collection 

of liquids and lead to an electric shock.

  1.  Carefully measure and cut the opening in the cabinet wall 

for the control panel.

  2.  Drill the appropriate holes around the cutout for the control 

panel mounting screws (not supplied).

Silicone Sealant

2-3/16″

(55 mm)

5-1/2″

(139 mm)

5-11/16″

(144 mm)

2-3/8″

(60 mm)

Control Panel Cutout and Screw Hole Dimensions

  3.  Apply a 1/4″ (6 mm) bead of NSF-approved silicone sealant 

where the trim on the control panel will contact the cabinet 

surface. Refer to the “Control Panel Cutout and Screw Hole 

Dimensions” illustration for silicone placement.

  4.  Position the control panel into the cutout opening through 

the front of the cabinet. Make sure to embed the trim on the 

control panel into the silicone.

  5.  Fasten the control panel to the vertical surface using four 

mounting screws (not supplied). 

  6. Connect the control cable from the control panel to the 

bottom of the well.

  7.  Install the cable tie using the supplied screw. The cable tie 

is used to keep the control cable orderly under the unit.

Mounting Screw

Control Cable

Silicone

Sealant

Cabinet Wall

Cabinet Wall

Installing the Control Panel

NOTE: The control box is 1-5/8″ (40 mm) deep, make sure to 

leave enough clearance inside cabinet.

INSTALLATION

Содержание IWEL Series

Страница 1: ...haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual contiene im...

Страница 2: ...formance Every unit is inspected and tested thoroughly prior to shipment Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specificati...

Страница 3: ...and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle Remote mounted control panel must be mounted on a vertical wall and i...

Страница 4: ...ill not operate Induction Dry Wells are designed to be installed into a variety of solid material countertops The unit includes a remote control panel that connects to the induction well with a 78 200...

Страница 5: ...an to determine and install proper voltage and size electrical receptacle NOTE The specification label is located on the bottom of the unit See label for serial number and verification of unit electri...

Страница 6: ...prepare the installation site described in the Preparing the Installation Site area in this section Avoid areas that may be subject to active air movements or currents i e near exhaust fans hoods air...

Страница 7: ...can be installed using the standard drop in countertop method or an undermount method Refer to the appropriate procedure below for the desired method of installation Countertop Installation Use the f...

Страница 8: ...ion well Two under mount options can be used Follow the desired under mount procedure Under Mount using Flanged Countertop 1 Carefully measure and cut the flanged opening in the countertop Use the Fla...

Страница 9: ...sealant must be rated for use at temperatures up to 250 F 121 C 7 Install the control panel Refer to the Installing the Control Panel procedure Installing the Control Panel Use the following procedure...

Страница 10: ...ll spills and splashes immediately Make sure unit is dry before using Do not allow liquid to run into the unit NOTE The unit can be turned off at any time by pressing the button The internal memory wi...

Страница 11: ...ature setpoints up or down during operation to find the best setting for a particular pan amount of food and heating desired Once a good setpoint has been determined use this setting in the future for...

Страница 12: ...from an external USB drive NOTE For the latest firmware updates go to the Hatco website www hatcocorp com Click on the Resources drop down menu and select Firmware Download 1 Turn off the unit by pres...

Страница 13: ...Authorized Hatco Service Agent or contact the Hatco Service Department at 414 671 6350 CAUTION Use only wipes pads and cleaners designed specifically for cleaning ceramic glass surfaces Wipe up all sp...

Страница 14: ...umber Non Warranty Problems If you experience a non warranty problem that requires assistance please contact the nearest Authorized Hatco Service Agency To locate the nearest Service Agency log onto o...

Страница 15: ...er Warmer Elements metal sheathed Drawer Warmer Drawer Rollers and Slides Food Warmer Elements metal sheathed Display Warmer Elements metal sheathed air heating Holding Cabinet Elements metal sheathed...

Страница 16: ...ilit maximale une apparence attractive et des performances optimales Chaque appareil est soigneusement inspect et test avant exp dition Informations Importantes pour le Propri taire 16 Introduction 16...

Страница 17: ...lorsque vous touchez ces surfaces AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Branchez l appareil une prise de courant mise la terre et pr sentant la tension la taille et la configuration ad quates Si...

Страница 18: ...onserver les aliments une temp rature sans danger NOTA les puits secs induction sont destin s maintenir les aliments chauds et non les cuire Poign e du plateau Plateau ajustable Avant de l appareil C...

Страница 19: ...t de tension correctes NOTE The specification label is located on the bottom of the unit Consultez la plaque signal tique pour conna tre le num ro de s rie et v rifier les caract ristiques lectriques...

Страница 20: ...ette section Veillez bien pr parer le lieu d installation tel que cela est expliqu dans la partie Pr parer le lieu d installation de cette section vitezleszonespouvant tresoumises desd placements d ai...

Страница 21: ...rd d installation en surface ou de la m thode d installation sous plan Reportez vous aux proc dures ci dessous correspondant la m thode d installation souhait e Installation en surface Suivez la proc...

Страница 22: ...llation sous plan Suivez la proc dure correspondant l installation sous plan souhait e Installation sous plan rebords 1 Prenez soigneusement les mesures n cessaires et pratiquez une d coupe dans le pl...

Страница 23: ...pr vu pour une utilisation une temp rature pouvant atteindre 121 C 250 F 7 Installez le panneau de commande Veuillez vous r f rer la proc dure Installer le panneau de commande Installer le panneau de...

Страница 24: ...gler la temp rature de l appareil Bouton marche arr t Le bouton marche arr t sert mettre l appareil sous ou hors tension Fonctionnement de l appareil Mise en service 1 Chaque jour avant d allumer l a...

Страница 25: ...n la valeur de consigne de l affichage de commande correspondant commence clignoter 2 Dans les 5 secondes qui suivent appuyez sur les boutons et pour s lectionner la temp rature de consigne souhait e...

Страница 26: ...du panneau de commande Suivez la proc dure suivante pour verrouiller les boutons du panneau de commande 1 Maintenez appuy s les boutons et pendant 3 secondes pour verrouiller le panneau de commande La...

Страница 27: ...tiques leur permettant de fonctionner sans danger dans le mat riel Hatco AVERTISSEMENT Cet appareil ne contient aucune pi ce r parable par l utilisateur Si cet appareil doit tre r par contactez un r p...

Страница 28: ...e interne La temp rature interne de l unit a d pass la limite de s curit teignez l unit et laissez la refroidir pendant au moins 30 minutes avant de la rallumer Si l erreur ne dispara t pas contactez...

Страница 29: ...ntrez un probl me ne relevant pas de la garantie et pour lequel vous avez besoin d aide veuillez contacter l agence d entretien agr e Hatco la plus proche Pour trouver l agence d entretien la plus pro...

Страница 30: ...ppe m tallique l ments de pr sentation du r chaud enveloppe m tallique air chauffant l ments des armoires de stockage enveloppe m tallique air chauffant l ments de puits chauffants s ries HW HWB et HW...

Страница 31: ...IWELM 0123 31 Fran ais NOTAS...

Страница 32: ...5 3Wire Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 3...

Отзывы: